Specification |
Application: Electronic, Instrument, Meter;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: PCB Mount;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
|
Application: Electronic, Instrument, Position Sensor;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Ratio: 1000: 1 or 2000:1 , Customized;
Key Words: Current Transformers for Metering;
Key Word: DBP 100 5 Split Ct's;
Model: DBP Split Core Current Transformer;
Rated Voltage: 720V;
Accuracy Class: 0.2%, 0.5 %, 1%;
Rated Primary Current: 20 a/30A/40A/50A/60A/80A/100A/150A/200A;
Output Signal: 10mA-200mA Acoptional 333mv AC or 100mv-2V Optonal;
Frequency Range: 40 Hz-500 Hz;
Max. Jaw Opening: 16 mm;
|
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Standards: IEC60044-1; IEC 61869-2; Ntc 2205; GB1208-2006;
Rated Primary Current: 30-600A;
Rated Load: ≤10va;
Rated Frequency: 50Hz or 60Hz;
Rated Secondary Current: 5A or 1A;
Instrument Security Factor: Fs≤10;
Weight (Kg): 1.6;
|
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Keyword: Clamp Transformer;
Model: 1000A AC Clamp Transformer;
P50: AC Measurement Clamp Transformer;
Ratio: 1000: 1 or 2000:1 (Customized);
Accuracy Class: 0.1%, 0.2%, 0.5%;
Primary Current: 0 - 1000A AC;
Secondary Current: 1mv/a AC, 5mv/a or (Customized);
Standard: En 61010-1, En 61010-2-032, IEC60044-1;
Weight (G): 550;
Max. Jaw Opening (mm): 50;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting, Current, Power Energy, Monitoring;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Customized: Customized;
Display: Digital;
Stucture: Transformer;
Voltage: Low Voltage;
Brand: Grewin Clamp on Sensor;
Maximum Voltaget600VAC: Rated Primary Currentt0.1A-1000A;
Maximum Non-Destructive Current: 2000A;
Current Probe Transformer Basic Accuracy: 1%;
Dielectric Resistance: 1000mohms @ 500 VDC;
Maximum Cable Diameter: 2.05 Inches (52 mm);
Approval: RoHS Compliant CE&ETL Approved;
Rated Output: 5A, 1A;
Core Material: Both Silicon Steel & Nickel Alloy Cores Available;
Current Sensor: Current Clamps with 0.333mv Output;
|