Specification |
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hengfengyou;
Rated Capacity: 50-31500 kVA;
H.V. Winding: 33kv11kv;
L.V. Winding: 0.4kv;
Vector Group: Dyn11 Yyn0;
No-Load Loss: 0.16-2.36kw;
No-Load Current: 0.55- 1.3%;
Short-Circuit Impedance: 1.3-0.55 %;
|
Application: Power, Electric;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer, Utilities, Renewable, Oil and Gas, etc;
Frequency Characteristics: 50/60Hz;
Shape of Core: Stacked Iron Core;
Brand: Daelim Belefic;
Rated Capacity: 5000kVA and Others;
Rated High Voltage: 13.2kv, 13.8kv, 34.5kv and Others;
Rated Low Voltage: 208/120V, 415/240V, 480V, 600V, etc;
Color: Grey and Others;
Temperature Rise: 55/65 Degree C;
Coil Number: 2;
Coil Structure: Toroidal;
Type: Oil-Type;
Core Material: Silicon Steel Sheet;
Cooling: Onan/Knan;
Warranty: 2 Years;
Winding Material: Aluminum/Copper;
Hv Bushing: Side Mounted/Top Mounted;
LV Bushing: Side Mounted/Top Mounted;
Accessories: Tap Changer, Load Break Switch, Arresters, etc;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: Shengte;
Rated Capacity: 400kVA;
High Voltage: 10/11kV;
Low Voltage: 0.4kV;
Impedance Voltage: 4%;
No-Load Loss: 0.57kW;
Load Loss: 4.52/4.3kW;
No-Load Current: 1.3%;
Frequency: 50/60Hz;
Connection Method: Yyn0/Dyn11;
Material: Aluminum/Copper;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Single;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Auto-transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Power Transformer;
Frequency Characteristics: Low Frequency;
Shape of Core: EI;
Brand: OEM;
|
Application: Power, Electric;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer, Utilities, Renewable, Oil and Gas, etc;
Frequency Characteristics: 50/60Hz;
Shape of Core: Stacked Iron Core;
Brand: Daelim Belefic;
Rated Capacity: 5000kVA and Others;
Rated High Voltage: 13.2kv, 13.8kv, 34.5kv and Others;
Rated Low Voltage: 208/120V, 415/240V, 480V, 600V, etc;
Color: Grey and Others;
Temperature Rise: 55/65 Degree C;
Coil Number: 2;
Coil Structure: Toroidal;
Type: Oil-Type;
Core Material: Silicon Steel Sheet;
Cooling: Onan/Knan;
Warranty: 2 Years;
Winding Material: Aluminum/Copper;
Hv Bushing: Side Mounted/Top Mounted;
LV Bushing: Side Mounted/Top Mounted;
Accessories: Tap Changer, Load Break Switch, Arresters, etc;
|