Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electromagnetic;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: RCBO;
Poles Number: 3p+N;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Working Voltage: 380/400/415 V;
Mechanical Life: 10,000 Times;
Electric Life: 4000 Times;
Protection Level: IP20;
Rate Current: 40A;
Residual Current: 100mA;
|
Breaking Capacity: High Voltage Circuit Breakers, High Voltage Circuit Breakers;
Operation: Electric Type, Electric Type;
Speed: Normal Type Circuit Breaker, Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum, Vacuum;
Installation: Fixed, Fixed;
Structure: ACB, ACB;
Poles Number: 3, 3;
Type: Circuit Breaker, Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB, Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Electricity Type: Vacuum;
Number of Pole: 1;
Phase: 1/2/3;
Main Circuit Rating Voltage: 12KV;
Main Circuit Rating Current: 630/1250A;
Name: Vacuum Interrupter;
Shelf life: 20years;
Color: Silver, Copper;
Afterserivce: Yes;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: RCBO;
Poles Number: 2;
Type: Circuit Breaker;
Function: Overcurrent Protection, OVP(Overvoltage Protection), RCCB, short circuit;
Standard: IEC 61009-1;
Pole: 1P+N;
Tripping curve: C;
Rated Current (in): 40a;
Mode: Electronic;
Residual Current Type: Ac;
Residual Current (LΔn): 30mA;
Icn: 10kA;
Energy limiting class: 3;
Electrical Life: 20, 000;
Mechenical Life: 20, 000;
keywords: circuit breaker;
keywords2: RCBO;
keywords3: GFCI;
ISO: 9001, 14001, 45001;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Lbs;
Poles Number: 3;
Type: Fn3-12 Vacuum;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Customization: Acceptable;
Currency: RMB or USD;
Language: Chinese, English, Russian;
Loading Port: It Depends;
Frequency: 50Hz;
Rated Voltage: 12kv;
Rated Current: 630A;
Mechanism Type: Manual;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Lbs;
Poles Number: 3;
Type: Fzw28-12f;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Customization: Acceptable;
Currency: RMB or USD;
Language: Chinese, English, Russian;
Loading Port: It Depends;
Frequency: 50Hz;
Rated Voltage: 12kv;
Rated Current: 63A;
Operating Environment: Outdoor;
|