Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electromagnetic;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: RCCB;
Poles Number: 1p+N;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Mechanical Life: 10,000 Times;
Electric Life: 4000 Times;
Protection Level: IP20;
Rated Working Voltage: 240V/415V;
Rated Current: 32A;
Rated Residual Current: 100mA;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: RCBO;
Poles Number: 2p/4p;
Type: a/AC;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Voltage: 230V/440V AC;
Inc: 6ka;
Tripping Curve: B/C/D;
IP Grade: IP20;
Rated Current: 6-63A;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Electricity Type: Vacuum;
Phase: 3;
Number of Pole: Fixed;
Main Circuit Rating Voltage: 12;
Main Circuit Rating Current: 2000A;
Name: Embedded poles;
Shelf life: 20years;
Afterserivce: Yes;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Electricity Type: Vacuum;
Phase: 3;
Number of Pole: Fixed;
Main Circuit Rating Voltage: 12;
Main Circuit Rating Current: 2500A;
Name: Embedded poles;
Shelf life: 20years;
Afterserivce: Yes;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: RCBO;
Poles Number: 2p/4p;
Type: a/AC;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Voltage: 230V/440V AC;
Inc: 6ka;
Tripping Curve: B/C/D;
IP Grade: IP20;
Rated Current: 6-63A;
|