Specification |
Classification: Imaging Diagnostic Equipment;
Type: Digital Imaging System;
Group: Middle-aged and Old;
Power Supply Voltage and Frequency: 85~264VAC;
Power Supply Power: 100-400W;
Ambient Temperature: -20ºC~80ºC;
Use Gas: Medical Grade CO2;
Working Pressure Range: 0-25mmhg;
Gas Flow: 30L;
|
Classification: Biological Diagnostics;
Group: Middle-aged and Old;
Model No.: Bke-L;
Measuring Speed: ≤25s;
Bke-L Test Items: K, Na, Cl, Ica, Nca, TCA, pH, Li, Mg, Tco2, AG;
Analysis Method: Lon Selective Electrode (ISE);
Sample Volume: 60-300UL (3 Parameters to 11 Parameters);
Sample Position: 35 Positions (Including 1 QC);
Storage: up to 10,000 Test Results;
Power Supply: RS232 Port;
Wavelengthindicationerro: 220/110V;
Temperature: 5-40ºC;
Relative Humidity: ≤ 80 %;
Atmospheric Pressure: (86~106) Kpa;
Package Size(W*D*H): 490*390*700mm;
Interface: RS-232;
Gross Weight: 27kg;
|
Classification: Biological Diagnostics;
Group: Middle-aged and Old;
Model No.: Bke-L;
Measuring Speed: ≤25s;
Bke-L Test Items: K, Na, Cl, Ica, Nca, TCA, pH, Li, Mg, Tco2, AG;
Analysis Method: Lon Selective Electrode (ISE);
Sample Volume: 60-300UL (3 Parameters to 11 Parameters);
Sample Position: 35 Positions (Including 1 QC);
Storage: up to 10,000 Test Results;
Power Supply: RS232 Port;
Wavelengthindicationerro: 220/110V;
Temperature: 5-40ºC;
Relative Humidity: ≤ 80 %;
Atmospheric Pressure: (86~106) Kpa;
Package Size(W*D*H): 490*390*700mm;
Interface: RS-232;
Gross Weight: 27kg;
|
Classification: Biological Diagnostics;
Type: Biochemistry Analyzer;
Group: Hospital;
Product Name: Auto Chemistry Analyzer;
Throughput: 200 Tests/Hour;
Temperature Control: 37+0.1 Degree, Real-Time Monitoring;
Reagent Position: 28 Reagent Positions;
Lis System: Bi-Direction,Support Hl7 Protocol;
Temperature: 10~30 Degree;
Power Supply: AC220V,50/60Hz, 110V,60Hz, 300W;
Gross Weight(Kg): 130kg;
Package Size(W*D*H)mm: 1118*728*1151mm;
Place of Origin: Shandong, China;
Model Number: Bk-200;
Brand Name: Biobase;
Warranty: 1 Year;
Sample Volume: 2~70UL;
Reaction Tray: 48 Reusable Cuvettes (Optical Path Length 6mm);
|
Classification: Biological Diagnostics;
Group: Middle-aged and Old;
Measurementchannel: Vertical 8 Optical Channels;;
Wavelength Range: 400~800 Nm;
Filter: Standard Four Wavelengths of 405, 450, 492, 630n;
Readingrange: 0.000~4.000 ABS;
Linearrange: 0.000~3.000 ABS;
Repeatability: CV≤1.0%;
Stability: ≤±0.003ABS;
Absorbanceaccuracy: Absorbance Value [0.0~1.0];
Wavelengthindicationerro: ≤±2nm;
Wavelengthrepeatability: ≤±1.5nm;
Powersupply: AC220V, 50Hz;
Linearityrange: Wbc: 0.0-99.9(×10^9/L);
Testing Items: Wbc Ly Ly% Mo Mo% Gr Gr% Rbc Hgb Hct Mcv Rdw-SD;
Interface: RS-232;
Packingsize (W*D*H): 535mm*395mm*395mm;
|