Specification |
Display: Indicator;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: Pulse Peak;
Type: Energy Meter;
Customized: Customized;
Product Type: 3 Phases 4 Wires DIN Rail Meter;
Ref. Voltage: 3*220/380V;
Ref. Current: 3*1.5(6)a;
Impulse Constant: 10000imp/Kwh;
LCD Display: LCD5+3;
Operation Temp.: -20~+70 Degree;
Average Humidity: 75%;
Max Humidity: 95%;
Ref. Frequency: 50Hz;
Accuracy Class: Active Cl.0.5, Reactive Cl.1.0;
Starting Current: 0.001ib;
Power Consumption: <8va, <0.4wh;
Standard Compliant: IEC62052-11,IEC62053-21;
Impulse Indicator: The Width of Impulse Indication Is 40ms;
|
Display: LCD;
Installation: Indirect Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Reactive Energy Meter, Multi-rate Watt-hour Meters;
Electric Equipment: Single-phase;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: Pulse Peak;
Type: Energy Meter;
Customized: Non-Customized;
Product Name: Adl100-Ey Single Phase Prepaid Energy Meter;
Brand: OEM ODM;
Rated Voltage: 220V;
Voltage Reference Frequency: 50/60Hz;
Input Current: 10(60)a;
Display Type: -20 ~+70 Centigradelcd;
Communication: RS485 Modbus RTU;
Storage Temperature: -40 Centigrade ~70 Centigrade;
|
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Type: Energy Meter;
Customized: Customized;
Model: DTZY876;
Basic Current (Ib): 10A;
Maximum Current (Imax): 100A;
Starting Current: 30mA;
Rated Voltage (Un): 3*230V/400V;
Operating Voltage: 0.6-1.3Un;
Frequency: 50Hz/60Hz;
Accuracy Class: 1.0;
Pulse Constant: 400imp/kWh;
Protection Level: IP54;
Operating Temperature: -25~70;
Humidity: Less Than 85%RH;
Insulation Class: 2.0;
Power Consumption: <1.5W,6VA;
Number of Display: 8;
|
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter;
Electric Equipment: Three-phase Four-wire;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Type: Energy Meter;
Customized: Customized;
Model: DTZY876;
Basic Current (Ib): 10A;
Maximum Current (Imax): 100A;
Starting Current: 30mA;
Rated Voltage (Un): 3*230V/400V;
Operating Voltage: 0.6-1.3Un;
Frequency: 50Hz/60Hz;
Accuracy Class: 1.0;
Pulse Constant: 400imp/kWh;
Protection Level: IP54;
Operating Temperature: -25~70;
Humidity: Less Than 85%RH;
Insulation Class: 2.0;
Power Consumption: <1.5W,6VA;
Number of Display: 8;
|
Display: Digital;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter, STS;
Electric Equipment: Single-phase;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Type: Energy Meter;
Customized: Customized;
Model: DDZY876;
Basic Current (Ib): 1.5A/2.5A/5A/10A/15A/20A/30A;
Maximum Current (Imax): 6A/15A/40A/60A/80A/100A;
Starting Current: 0.004Ib;
Rated Voltage (Un): 220V/230V;
Operating Voltage Range: 0.6-1.3Un;
Frequency: 50Hz/60Hz;
Accuracy Class: 1.0;
Pulse Constant: 1000imp/kWh;
Protection Level: IP54;
Operating Temperature: -25~70;
Humidity: Less Than 85%RH;
Insulation Class: 2.0;
Power Consumption: <1.5W, 6VA;
Number of Display Digits: 8;
|