Specification |
After-sales Service: Online;
Warranty: 1year;
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: Speed;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Ordinary;
Excitation Mode: AC Rotating Exciter;
Starting Method: 24V DC Start Battery;
Fuel Tank: 8-24 Hours Working Time;
Optional: ATS,Oil Heater,Engine Heater,Separator;
Controller: Deep Sea,Comap,Smartgen;
Alternator: Stam Ford,Marathon,Hengsheng;
Certificate Available: CE, ISO, OEM Authorization etc.;
Engine: Googol Power;
Power Section: 400kVA-3000kVA;
Controllers: Dse8610mkii, Hgm9530, AGC150;
Product Description: Open Diesel Generator Set;
Brushless Alternator: AC 220V, 380V, 400V, 4. 15V, 440V, 480V, 50Hz/60Hz;
Protection Function: Manual/Auto Start Control System;
Absorbers: Anti Vibration Suspension Absorbers;
Breaker/ ATS: Main Line Circuit Breaker/ ATS;
Batteries: Big Capacity Start Batteries;
|
After-sales Service: Global After-Sales;
Warranty: 1 Year;
Type: Basic Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: Speed;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit;
Landuse Type of Unit: Ordinary;
Excitation Mode: AC Rotating Exciter;
Genset Type: Open/Silent/Trailer/Container;
Date of Delivery: 3-7 Working Days;
ODM/OEM: Yes;
MOQ: 1 Set;
|
After-sales Service: Global After-Sales;
Warranty: 1 Year or Running 1000 Hours;
Type: Basic Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: Speed;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit;
Landuse Type of Unit: Low Noise;
Excitation Mode: AC Rotating Exciter;
Genset Type: Open/Silent/Trailer/Container;
Date of Delivery: 3-7 Working Days;
ODM/OEM: Yes;
MOQ: 1 Set;
|
Warranty: 1 Year;
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: Speed;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Low Noise;
Excitation Mode: AC Rotating Exciter;
Rated Power: 250kw/313kVA;
Rated Voltage: 400/230V;
Rated Current: 451A;
Frequency/Speed: 50Hz/1500rpm;
|
Warranty: 1 Year;
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: Speed;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Low Noise;
Excitation Mode: AC Rotating Exciter;
Rated Power: 300kw/375kVA;
Rated Voltage: 400/230V;
Rated Current: 541A;
Frequency/Speed: 50Hz/1500rpm;
|