Specification |
After-sales Service: 24 Hours;
Warranty: 1year;
Accuracy: ±0.6-1%;
Main Application: Water, Wastewater, Fuel Oil, Milk\ Soybean Oil \Clearwater;
Size: DN4-DN200;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Turbine Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Output Type: Pluse Output;
Medium: Liquid;
Communication Protocol: 1.6MPa;
Temperature: Normal Temperature;
|
After-sales Service: Served;
Warranty: 12 Months;
Main Application: Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas, Lithium-Ion Battery;
Size: DN50-100;
Sensor: Tube/Flange;
Application: Transportation;
Type: Coriolis Mass Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Coriolis;
Measurement Object: Open Channel;
Measure Parameters: Mass Flow, Temperature, Density, Volume Flow.;
Measurement Method: Directly Measure Mass Flow;
Measurable Medium: High-Viscosity , Liquids with Trace Solids;
Measurement Accuracy Affected Factor: Only by Vibration;
Installation Requirements: No Need to Consider Upstream and Downstream;
Measurement Accuracy Affected Facto: Only by Vibration;
Installation Requirement: Not Need to Consider The Upstream and Downstream;
Measuring Medium: Gas, Liquid and Multi-Phase Flow;
|
After-sales Service: Support 1 Year Warranty;
Warranty: 1 Year;
Accuracy: ±0.1% of Span;
Main Application: Water;
Size: DN50-100;
Sensor: Tube/Flange;
Application: Environmental Protection;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Open Channel;
Product Name: Emerson Micro Motion 1700 Mass Flow Meter;
Measured Variables: Coriolis Mass Flow, Volume Flow, Density, Temperat;
Mass Flow Accuracy: ±0.1% of Rate (Standard), ±0.05% Opt;
Density Accuracy: ±0.0005 G/Cm³ (Liquids), ±0.002;
Temperature Accuracy: ±1°c (PT100 Rtd Integrated);
Flow Range: 0.01 Kg/H to 1, 000, 000 Kg;
Process Connections: Flanged (ANSI/DIN/JIS), Threaded (NPT/Bsp), Sanita;
Materials: 316L Stainless Steel, Hastelloy C-22, Alloy C-276;
Output Signals: 4–20 Ma (Isolated), Hart® 7, Foundation;
Power Supply: 18–30 V DC (Loop-Powered/External), <15 W Po;
Operating Temperature: -40°c to +85°c (-40°f to +185°f);
Storage Temperature: -50°c to +90°c (-58°f to +194°f);
Humidity: 5–95% Rh (Non-Condensing);
Sensor Tube Design: Straight or Curved Coriolis Tubes (No Moving Parts;
Vibration Resistance: 5g RMS (10–150 Hz);
|
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Conductive Liquid;
Size: DN10-350;
Sensor: Tube/Flange;
Application: Energy Metering;
Type: Coriolis Mass Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Coriolis Effect;
Measurement Object: Closed Pipeline;
|
After-sales Service: on Line;
Warranty: 12 Months;
Accuracy: +/- 0.1%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas;
Size: DN10-50;
Sensor: Clamp-on/External;
Application: Energy Metering;
Type: Coriolis Mass Flow Meter;
Measuring Media: Gas;
Measuring Principle: Coriolis;
Measurement Object: Open Channel;
Measure Parameters: Mass Flow, Temperature, Density, Volume Flow.;
Measurement Method: Directly Measure Mass Flow;
Special Medium: Gases with Minimal Liquid Content;
Installation Requirements: No Need to Consider The Upstream and Downstream St;
|