Specification |
Accuracy: >±1%;
Main Application: Nature Gas, Ammonia Gas Air;
Size: Dn10-Dn1000;
Sensor: Plug-in;
Application: Industrial Production;
Type: Coriolis Mass Flow Meter;
Measuring Media: Gas;
Measuring Principle: Thermodynamic;
Measurement Object: Closed Pipeline;
Output Type: Pluse,4-20mA ,RS485and GPRS,Hart;
Power Supply Type: 24VDC or 220VAC;
|
After-sales Service: Free Guidance and Maintenance;
Warranty: 12 Months;
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Corrosive Liquid/Gas, Sea Water ,Acid, Base;
Size: DN10~DN3000;
Sensor: Tube/Flange;
Application: Environmental Protection;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Nominal Pressure: 0.6--4.0MPa (Customized;
Power Supply: 220VAC/ 24VDC;
Signal Output: Pulse/ Frequency/4-20mA;
Medium Temperature: -20~160 (Customized);
Electrode: Customized;
Protection Grade: IP 65 / IP 68;
Electrode Material: SUS316L;
Ambient Temperature: -25~60;
Communication: RS485 Modbus;
|
After-sales Service: Free Guidance and Maintenance;
Warranty: 12 Months;
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Corrosive Liquid/Gas, Sea Water ,Acid, Base;
Size: DN10~DN3000;
Sensor: Tube/Flange;
Application: Environmental Protection;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Nominal Pressure: 0.6--4.0MPa (Customized;
Power Supply: 220VAC/ 24VDC;
Signal Output: Pulse/ Frequency/4-20mA;
Medium Temperature: -20~160 (Customized);
Electrode: Customized;
Protection Grade: IP 65 / IP 68;
Electrode Material: SUS316L;
Ambient Temperature: -25~60;
Communication: RS485 Modbus;
|
After-sales Service: Free Guidance and Maintenance;
Warranty: 12 Months;
Accuracy: ±1%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil;
Size: DN15-DN6000;
Sensor: Clamp on;Insertion;Inline;
Application: Environmental Protection;
Type: Ultrasonic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Transit Time Difference;
Measurement Object: Closed Pipeline;
Power Consumption: Less Than 1.5W;
Power Supply: 90-230VAC;
Interface: RS485;
Temperature: Main Unit: -30c - 80c;
Protection Grade: IP 65 / IP 68;
Repeatability: Better Than 0.2%;
Measurement Period: 500ms;
Display: LCD with Backlight;
|
After-sales Service: Free Guidance and Maintenance;
Warranty: 12 Months;
Accuracy: ±1%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil;
Size: DN15-DN6000;
Sensor: Clamp on;Insertion;Inline;
Application: Environmental Protection;
Type: Ultrasonic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Transit Time Difference;
Measurement Object: Closed Pipeline;
Power Consumption: Less Than 1.5W;
Power Supply: 90-230VAC;
Interface: RS485;
Temperature: Main Unit: -30c - 80c;
Protection Grade: IP 65 / IP 68;
Repeatability: Better Than 0.2%;
Measurement Period: 500ms;
Display: LCD with Backlight;
|