Specification |
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Hermetically Sealed Relay;
Installation: Fixed;
Structure: ACB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Theory: Electromagnetic Relay;
Usage: Household Appliances Relay;
Texture: Metal;
Easy to Install: Made Exactly Fit for Most Brands.;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3p, 4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Cooperation Type: ODM OEM;
Factory: Own;
Production Line: 100% Automatic;
Payment: L/C, T/T, D/P, Western Union, Paypal, Money Gram;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: MCB;
Poles Number: 1p/2p/3p/4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Voltage Ui: 1000V;
Imp: 6ka/10ka;
Rated Current: 63A;
Tripping Curve: B/C;
Enclosure Box: with/Without;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: IEC 60898-1 & GB 10963.1;
Rated curret (In): 1A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A;
Trip curve: B, C, D;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 240V/415V ; 2/3/4P: 415V;
Insulation voltage(Ui): 500V;
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated breaking capacity (Icn): 10kA;
Rated operating short circuit breaking c: 7.5kA;
Rated impulse withstand voltage (Uimp): 4kA;
Electrical life: 4000;
Pollution degree: 3;
Mechanical life: 20000;
Protection degree: IP20;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Insert;
Structure: MCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Frame Current: 100A;
Rated Current: 16/25/32/40/63/80/100A;
Rated Voltage: 230/400V;
Rated Impulse Voltage: 500V;
Rated Operating Frequency: 50/60Hz;
Pole: 2p/4p;
Trip Curve: B/C/D;
Remaining Action Type: AC or AC Type;
Rated Impulse Withstand Voltage: 4kv;
Mechanical Life: 10000times;
Electrical Life: 6000times;
Rated Short-Circuit Breaking Capacity: 6/10ka;
Protection Degree: IP20;
Rated Working System: Uninterrupted Working System;
Ambient Air Temperature: -5 - +40ºC;
|