Specification |
Application: Electronic, Instrument, Vacuum Circuit Breaker;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Penetration Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Standard: IEC61869-2;
Rated Voltage: 10kv;
Class: 5p, 10p;
Secondary Current: 5A or 1A;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Input Current: 0~1500A;
Rated Capacity: 0~5va;
Accuracy Class: 0.5, 1.0;
Winding Bobbin: PBT;
Rated Frequency: 50/60Hz;
Opening-Closing Structure: Snap;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Switchgears;
Phase: Three;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Busbar Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Photoelectric Type;
Brand: Bdn;
Insulation: Casting Insulation;
Rated Current: 1250;
Rated Voltage: 10/12;
Rated Frequency: 50;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Switchgears;
Phase: Three;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Busbar Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Photoelectric Type;
Brand: Bdn;
Rated Voltage: 10/12;
Rated Frequency: 50;
Rated Current: 1250;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting, Harvesting Energy;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement, Power Supply;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Coil Structure: Toroidal;
Core: Permalloy;
Input Current: 5A;
Output Power: 72MW;
Cross-Sectional Area(mm²): 210;
No-Load Voltage (V): 8;
|