Specification |
After-sales Service: Contatc with Us;
Type: Basic Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: 1500rpm;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Low Noise Automation Type;
Excitation Mode: AC Rotating Exciter;
Prime Power: 2000kw 2500kVA;
Stanby Power: 2200kw 2750kVA;
Controller: Deepsea;
Alternator: Stamford/Longkai/Leroy Somer/Meec Alte;
|
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: Low Speed;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Ordinary;
Excitation Mode: AC Rotating Exciter;
Engine Model: Perkins1104A-44tg2;
Voltage: 220V/127V 380V/220V 400V/230V 415V/240V 480V/277V;
Frequency: 50/60Hz;
Governor Type: Mechanical;
Rated Power/Standby Power: 80va/64kw / 88va/70.4kw;
Alternator Mounted: Stamford Uci224G;
Alternator Option: Leroysomer, Marathon, Yihua Yhg;
Controller: Smartgen, Deepsea, Comap, Datakom, Harsen, etc;
Color Available: White, Blue, Red, Yellow and Customized Color;
|
Warranty: 12 Months;
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: Speed;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Automation Type;
Excitation Mode: AC Rotating Exciter;
Prime Power: 100kw/125kVA;
Standby Power: 110kw/137kVA;
Engine: Cummins (6BTA5.9-G2);
Alternator: Leory Somer/Genlitec/Meccalte...;
Controller: Smartgen/Comap/Deepsea/Harsen;
Other Service: OEM / ODM;
Frequency: 50/60Hz;
Delivery Time: 15-25days;
Options: ATS, Silent Type, Trailer Type;
|
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: 1500(R/Min);
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Automation Type;
Excitation Mode: Brushless Self-Excitation;
Displacement: 7.252L;
|
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Speed: 1500(R/Min);
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Automation Type;
Excitation Mode: Brushless Self-Excitation;
Displacement: 9.839L;
|