Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Oil-immersed Type;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Voltage: 40.5kv;
Rated Current: 1250/1600/2000A;
Rated Frequency: 50/60Hz;
Model Number: 3 Poles;
Mechanism: Central Operating Mechansim;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed, Mounting on 35mm DIN Rail;
Structure: MCB;
Poles Number: 1p.2p.3p.4p;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Degree of Protection: IP20;
Number of Poles: 1p,1p+N,2p,3p+N and 4p;
Protection: Against Overload and Short Circuit;
Rated Current in: 0.5,1,2,3,4,6,10,13,16,20,25,32,40,50,63A;
Type of Terminal: Lug Type and Pin Type;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed, Mounting on 35mm DIN Rail;
Structure: MCB;
Poles Number: 1p.2p.3p.4p;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Degree of Protection: IP20;
Number of Poles: 1p,1p+N,2p,3p+N and 4p;
Protection: Against Overload and Short Circuit;
Rated Current in: 0.5,1,2,3,4,6,10,13,16,20,25,32,40,50,63A;
Type of Terminal: Lug Type and Pin Type;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed, Mounting on 35mm DIN Rail;
Structure: MCB;
Poles Number: 1p.2p.3p.4p;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Degree of Protection: IP20;
Number of Poles: 1p,1p+N,2p,3p+N and 4p;
Protection: Against Overload and Short Circuit;
Rated Current in: 0.5,1,2,3,4,6,10,13,16,20,25,32,40,50,63A;
Type of Terminal: Lug Type and Pin Type;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed, Mounting on 35mm DIN Rail;
Structure: MCB;
Poles Number: 1p.2p.3p.4p;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: En/IEC60898-1;
Degree of Protection: IP20;
Number of Poles: 1p,1p+N,2p,3p+N and 4p;
Protection: Against Overload and Short Circuit;
Rated Current in: 0.5,1,2,3,4,6,10,13,16,20,25,32,40,50,63A;
Type of Terminal: Lug Type and Pin Type;
Rated Insulation Voltage Ui: 500V;
Rated Impulse Withstand Voltage Uimp: 4kv;
Energy Limiting: Class 3.0;
Width: 17.8mm Per Pole;
|