Specification |
After-sales Service: Online Technical Support;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Advantage: High Resolution;
Principle: Classic Spectrometer;
Wavelengths: Visible Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Customized;
|
Application: Laboratory Apparatus;
Warranty: > 1Year;
Detection Method: Spectrophotometer;
Advantage: High Resolution;
Principle: Classic Spectrometer;
Wavelengths: UV Spectrometer;
Customized: Customized;
Optical System: Double Beam, Grating1200 Lines/mm;
Wavelength Range: 190~1100nm;
Spectral Bandwidth: 0.5, 1, 2, 4, 5nm;
Wavelength Accuracy: 0.3nm;
Wavelength Repeatability: Less Than 0.2nm;
Noise: 0.002A;
Display: LCD;
Photometric Mode: T, a, C, E;
Photometric Range: 0-200%T, -0.301-3.0A;
Detector: Silicon Photodiode;
|
After-sales Service: Online Support and Free Part;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Customized: Non-Customized;
Optical System: Single Beam, Grating 1200 Lines/mm;
Wavelength Range: 190~1100nm;
Spectral Bandwidth: 4nm;
Wavelength Accuracy: ± 0.5nm;
Wavelength Repeatability: ≤ 0.3nm;
Baseline Flatness: ± 0.002A;
Display: 480 * 272 65 Thousand True Color TFT LCD;
Photometric Mode: T, a, C, E;
Detector: Silicon Photodiode;
|
Application: Laboratory Apparatus;
Warranty: > 1Year;
Detection Method: Spectrophotometer;
Advantage: High Resolution;
Principle: Classic Spectrometer;
Wavelengths: Emission Spectrum Principle;
Customized: Customized;
Sensitivity K: 0.01ppm;
Sensitivity Na: 0.01ppm;
Li,Ca,Ba: 0.1 Ppm, 2 Ppm, 6ppm;
Range: 0-100, 0-160, 0-1000, 0-3000 Ppm;
Linearity K: 0.195ppm, 0.39~3.12ppm;
Linearity Na: 0.69ppm, 1.15-9.2ppm;
Mdl K: < 0.156mmol/L;
Repeatability: 1 % CV for 20 Consecutive Samples;
Response Time: <8s;
Sample Uptake: <6ml/Min;
Standard Accessories: Air Compressor;
|
After-sales Service: Online Support and Free Part;
Application: Laboratory Apparatus;
Warranty: > 1Year;
Detection Method: Spectrophotometer;
Advantage: High Resolution;
Principle: Classic Spectrometer;
Wavelengths: Infrared Spectrometer;
Customized: Non-Customized;
Light Source: Hamamatsu 150W Xenon Lamp;
Emission Monochromator: C-T Diffraction Grating;
Wavelength Accuracy: ±1nm;
Wavelength Repeatability: ≤0.5nm;
Linear Measurement(R): ≥0.995;
Stability: Better Than 1.5%/10min;
Fluorescence Display Value: 0.00~600.00;
Power Supply: AC110/220V±10%, 60/50Hz;
Packing Size(mm): 550*510*365;
Gross Weight(Kg): 14;
|