Specification |
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas;
Size: DN100-500;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Protection Class: IP65;
Environment Temperature: -20c~60c;
Output Signal: 4-20madc;
Alarm Output: Rated Value 30V DC, 100mA;
Communication Signal: RS485 Communication Protocol;
Load Resistance: 250omega~ 600omega;;
Diameter of Flowmeter: mm;
Rated Voltage of Power Supply: 220V AC: 100V~240V AC;
Wire Terminals: M3 Screw;
Housing Material: Aluminum Alloy;
|
After-sales Service: Maintenance & Refund;
Warranty: 1 Year;
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas;
Size: DN10 - DN2000;
Sensor: Thread / Flange / Clamp on;
Application: Industrial Production;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electromagnetic Flow Meter;
Measurement Object: Closed Pipeline;
Line Size: DN3-DN2000;
Working Temperature: -50-180 Deg.C;
Working Pressure: up to 42 MPa;
Housing Material: Carbon Steel, Ss 304, Ss 316;
Lining Material: Neoprene(Chloroprene Rubber ), PTFE, PFA, F46 Cera;
Electrode Material: Ss 316L, Hastelloy C, Hastelloy Alloy B, Nicke, Ti;
Power Supply: DC12-24V, 3.6V Lithium Battery;
Protection Level: IP 65 (Integrated Type), IP 68 (Remote Tupe);
Ambient Temperature: -20 - 55 Deg.C;
Ambient Pressure: 86 -106 Kpa;
Signal Output: P-Pulse, 4-20mA, RS 485, Hart;
Signal Transmission Distance: 1,000m;
Display: Mechanical and Digital Display;
Connection: Wafer Connection Thread Connection Flange Connecti;
Conductivity: 3/8" - 80" (DN10 - DN2000);
|
After-sales Service: Free Guidance and Maintenance;
Warranty: 12 Months;
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Corrosive Liquid/Gas, Sea Water ,Acid, Base;
Size: DN10~DN3000;
Sensor: Tube/Flange;
Application: Environmental Protection;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Nominal Pressure: 0.6--4.0MPa (Customized;
Power Supply: 220VAC/ 24VDC;
Signal Output: Pulse/ Frequency/4-20mA;
Medium Temperature: -20~160 (Customized);
Electrode: Customized;
Protection Grade: IP 65 / IP 68;
Electrode Material: SUS316L;
Ambient Temperature: -25~60;
Communication: RS485 Modbus;
|
After-sales Service: Free Guidance and Maintenance;
Warranty: 12 Months;
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Corrosive Liquid/Gas, Sea Water ,Acid, Base;
Size: DN10~DN3000;
Sensor: Tube/Flange;
Application: Environmental Protection;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Nominal Pressure: 0.6--4.0MPa (Customized;
Power Supply: 220VAC/ 24VDC;
Signal Output: Pulse/ Frequency/4-20mA;
Medium Temperature: -20~160 (Customized);
Electrode: Customized;
Protection Grade: IP 65 / IP 68;
Electrode Material: SUS316L;
Ambient Temperature: -25~60;
Communication: RS485 Modbus;
|
After-sales Service: Maintenance & Refund;
Warranty: 1 Year;
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas, Steam;
Size: DN 15-DN300(1/2" - 12"); DN 300-DN 1000 (Plug-in);
Sensor: Thread / Flange / Clamp on;
Application: Industrial Production;
Type: Vortex Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Vortex Flow Meter;
Measurement Object: Closed Pipeline;
Line Size: DN 15-DN300, DN 300-DN 1000;
Working Temperature: -40-330 Deg.C, -40-500deg.C;
Working Pressure: 4.0MPa;
Housing Material: 1Cr18Ni9Ti;
Atmospheric Pressure: 86 - 106 Kpa;
Humidity: 5% -95%;
Power Supply: 3.6V Battery,12V DC, 24V DC;
Protection Level: IP 65 / IP 67 / IP 68;
Ambient Temperature: -20 - 55 Deg.C;
Ambient Pressure: 86 -106 Kpa;
Signal Output: Pulse,4-20mA, RS 485;
Signal Transmission Distance: 1,000m;
Display: No and LCD Display;
Connection: Flange, Thread, Tri-Clamp on,Swagelok Connection;
Display Units: M3/H, Kg/Hr, Nm3/H;
|