High Performance High Resolution Inductively Coupled Plasma Optical Emission Spectrometer

About this Item
Details
Company Profile

Price

Min. Order Reference FOB Price

1 Piece US$62,912.00 / Piece

Sepcifications

  • After-sales Service on Line Service
  • Application Laboratory Apparatus
  • Warranty > 1Year
  • Detection Method Spectroscopic
  • Advantage High Sensitive
  • Principle New Spectrometer
  • Wavelengths Infrared Spectrometer
  • Dispersive Element Grating Spectrometer
  • Light Number Monochromator
  • Certification ISO9001, CE
  • Customized Customized
  • Transport Package Wooden Carton
  • Specification 1000(L) mm X610(W) mm X510(H) mm, 150 kg
  • Trademark NANBEI
  • Origin China
  • Model Number Icp-7700
  • Power Electronic
  • Usage Auto Testing Machine
  • Product Name Inductively Coupled Plasma Optical Emission Spect
  • Frequency Stability <0.01%
  • Output Power 700 W-1200W, in 50W Increments
  • Output Work Coil ID 25mm, 3 Turns
  • Electromagnetism Leakage Intensity <2V/M
  • Coaxial Nebulizer Concentric Nebulizer

Product Description

High performance high resolution Inductively Coupled Plasma Optical Emission Spectrometer Product Description Our Product •Feature and Description *Main unit 1.1Plasma excitation and impedance matching using automatic technology, low reflected power, standing-wave ratio (SWR) is less ...

Learn More

Absorption Spectrometer Manufacturer Comparison
Transaction Info
Price US $ 62912/ Piece US $ 4,499.00-4,995.00/ Piece US $ 8000/ Piece US $ 7000/ Piece US $ 6,180.00-6,600.00/ Piece
Min Order 1 Pieces 1 Pieces 1 Pieces 1 Pieces 1 Pieces
Trade Terms - - - - -
Payment Terms L/C, T/T, D/P, Western Union, Paypal, Money Gram, Insurance L/C, T/T, Western Union, Paypal L/C, T/T, Western Union, Money Gram L/C, T/T, Western Union, Money Gram L/C, T/T, Western Union, Paypal
Quality Control
Product Certification ISO9001, CE ISO9001, CE RoHS, ISO9001, CE RoHS, ISO9001, CE ISO9001, CE
Management System Certification ISO 9001, ISO 9000, ISO 20000, HSE, ASME ISO 9001 ISO 9001 ISO 9001 ISO 9001
Trade Capacity
Export Markets North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe South America, Domestic South America, Domestic North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
Annual Export Revenue - - > US $100 Million > US $100 Million -
Business Model OEM, ODM, Own Brand, Others OEM, ODM, Own Brand - - OEM, ODM, Own Brand
Average Lead Time Off-season: within 15 Day(s)
Peak-season: within 15 Day(s)
Off-season: within 15 Day(s)
Peak-season: 1 Month(s)
Off-season: within 15 Day(s)
Peak-season: within 15 Day(s)
Off-season: within 15 Day(s)
Peak-season: within 15 Day(s)
Off-season: within 15 Day(s)
Peak-season: 1 Month(s)
Product Attributes
Specification
After-sales Service: on Line Service;
Application: Laboratory Apparatus;
Warranty: > 1Year;
Detection Method: Spectroscopic;
Advantage: High Sensitive;
Principle: New Spectrometer;
Wavelengths: Infrared Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Customized;
Model Number: Icp-7700;
Power: Electronic;
Usage: Auto Testing Machine;
Product Name: Inductively Coupled Plasma Optical Emission Spect;
Frequency Stability: <0.01%;
Output Power: 700 W-1200W, in 50W Increments;
Output Work Coil: ID 25mm, 3 Turns;
Electromagnetism Leakage Intensity: <2V/M;
Coaxial Nebulizer: Concentric Nebulizer;
After-sales Service: Yes;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Wavelengths: /;
Dispersive Element: /;
Light Number: /;
Customized: Customized;
Light Path: 1mm;
Sample Volume: 1~2&mu;l;
Light Source: Xenon Lamp;
Detector: 3684-Element Linear Silicide CCD Array;
Detection Range: 190~850nm;
Wavelength Range: 190-1100nm;
Wavelength Accuracy: &plusmn; 1nm;
Wavelength Resolution: 2 Nm (Fwhm at Hg 546 Nm);
Accuracy of Absorbance: 0.002 ABS;
Absorbance Accuracy: 1% (0.76 Absorbance at 350nm);
Absorbance Range: 0.02~15ABS, Equivalent to 10mm;
Detection Time: Less Than 3s;
After-sales Service: International Support;
Application: Industrial;
Warranty: 1 Year;
Detection Method: Spectroscopic;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Wavelengths: X-ray;
Dispersive Element: Proportional Counter;
Light Number: X-ray;
Customized: Customized;
Measurement Range: Au, AG, Ni,Cu and Zn;
Net Weight: 32kg;
Packing Size: 62*49*59cm;
Certificate: CE, ISO;
After-sales Service: International Support;
Application: Industrial;
Warranty: 1 Year;
Detection Method: Spectroscopic;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Wavelengths: X-ray;
Dispersive Element: Proportional Counter;
Light Number: X-ray;
Customized: Customized;
Measurement Range: Au, AG, Ni,Cu and Zn;
Net Weight: 32kg;
Packing Size: 62*49*59cm;
Certificate: CE, ISO;
After-sales Service: Yes;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Customized: Customized;
Optical Path: 1/0.5/0.05mm Automatic Conversion;
Optical Range: 190-1100nm;
Sample Volume: 0.3-2.0&mu;l;
Light Source: Long Life Xenon Lamp;
Detector: 3864 Linear CCD Array;
Wavelength Scanning Range: 190-850nm;
Wavelength Accuracy: &plusmn;1nm;
Wavelength Resolution: 2nm (Fwhm Hg 546nm);
Absorbance Accuracy: 0.002ABS;
Absorbance Range: 0.002-300ABS (Equivalent to 10mm Optical Path);
Supplier Name

NANBEI INSTRUMENT LIMITED

China Supplier - Diamond Member Audited Supplier

Chongqing Drawell Instrument Co., Ltd.

China Supplier - Diamond Member Audited Supplier

Jiangsu Skyray Instrument Co., Ltd

China Supplier - Diamond Member Audited Supplier

Jiangsu Skyray Instrument Co., Ltd

China Supplier - Diamond Member Audited Supplier

Chongqing Drawell Instrument Co., Ltd.

China Supplier - Diamond Member Audited Supplier