Specification |
Type: Emergency Ventilator;
Used for: Adult, Child;
Display: 10.4 Inch High Visibility Color TFT Display;
Tidal Volume: Adjustable Range: 50~1500ml;
Respiratory Rate: 1~99bpm;
Pressure Limit: 1.0kpa~6.0kpa;
Inspiratory/Expiratory (I:E) Ratio: 4:1~1:4;
Peep: 0~10CMH2o;
Simv Rate: 1~20bpm;
Ventilation Mode: A/C, Ippv, Sippv, Imv, Simv, Standby, Spont, Manua;
Minute Volume: Greater Than or Equal to 18L;
Inspiratory Pressure Trigger: ~10~10CMH2o;
Tidal Volume Alarm: Upper Limit: 10~2000ml, Lower Limit: 0~1800ml;
Back up Power Supply: at Least 4 Hours;
Display Range: 0~2000ml;
Inspiratory Plateau: Adjustable From 0~50% of Inspiratory Time;
Adjustable Oxygen Concentration: 45~100%;
|
Type: Auto CPAP Machine, Non-Invasive Ventilator;
Used for: Adult, Child;
Model: B17;
Screen: 3.5 TFT LCD Display;
Work Mode: CPAP S S/T T;
Weight: with Humidifier:1.8kg;
Dimension: with Humidifier:255mm*170mm*112mm;
Sound Pressure Level: <30dba(10CMH2o);
Press: 4--20CMH2o;
Startpress(CMH2o): 4--20CMH2o;
Ipap(CMH2o): 4--20CMH2o;
Epap(CMH2o): 4--20CMH2o;
Isens Auto,1-6 Levels: Yes;
Parameter Monitor: Ipap/Epap/Bpm/Vt/Mv/Lk/I:E/Wm;
Alarm: Power Failure;
Data Record: Data Tramsmit : Statistics /Detailed Data;
|
Type: Auto CPAP Machine, Non-Invasive Ventilator;
Used for: Adult, Child;
Model: B17;
Screen: 3.5 TFT LCD Display;
Work Mode: CPAP S S/T T;
Weight: with Humidifier:1.8kg;
Dimension: with Humidifier:255mm*170mm*112mm;
Sound Pressure Level: <30dba(10CMH2o);
Press: 4--20CMH2o;
Startpress(CMH2o): 4--20CMH2o;
Ipap(CMH2o): 4--20CMH2o;
Epap(CMH2o): 4--20CMH2o;
Isens Auto,1-6 Levels: Yes;
Parameter Monitor: Ipap/Epap/Bpm/Vt/Mv/Lk/I:E/Wm;
Alarm: Power Failure;
Data Record: Data Tramsmit : Statistics /Detailed Data;
|
Type: Auto CPAP Machine, Non-Invasive Ventilator;
Used for: Adult, Child;
Model: B17;
Screen: 3.5 TFT LCD Display;
Work Mode: CPAP S S/T T;
Weight: with Humidifier:1.8kg;
Dimension: with Humidifier:255mm*170mm*112mm;
Sound Pressure Level: <30dba(10CMH2o);
Press: 4--20CMH2o;
Startpress(CMH2o): 4--20CMH2o;
Ipap(CMH2o): 4--20CMH2o;
Epap(CMH2o): 4--20CMH2o;
Isens Auto,1-6 Levels: Yes;
Parameter Monitor: Ipap/Epap/Bpm/Vt/Mv/Lk/I:E/Wm;
Alarm: Power Failure;
Data Record: Data Tramsmit : Statistics /Detailed Data;
|
Type: Non-Invasive Ventilator;
Used for: Adult, Child;
Group: Adult;
Function: Non-Invasive Ventilator;
Theory: Non-Invasive Ventilator;
LCD Display: 3.5 Inch Color TFT;
Ramp: 0-60min;
Islop: 1-6 Level;
Bpm: 3-40bpm;
Noise: <30dB;
Net Weight/Size: 2.2kg, 280*200*112mm(Host+Humidifier);
Data Download: TF Card 8g;
|