Specification |
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Rectifier Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: U;
Brand: Pearl;
Capacity: 100-2500kVA;
Rated H. V.: 10kv;
Rated L. V.: 0.4kv;
Vector Group: Dyn11/Yyn0;
Reference Standards: IEC60076 Power Transformer;
Optional Accessories: Temperature Control, Fans, Enclosures, CT;
Type: Transformer;
No Load Loss: Customized;
Load Loss (@75°c): as Technical Specification;
Load Loss (@120°c): as Technical Specification;
Impedance: Customized;
Insulation Class (Hv/LV): H;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Oil Immersed Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Brand: Pearl;
Type: Oil Immersed Distribution Transformer;
Reference Standards: IEC 60076;
Capacity: up to 150mva;
Rated H. V.: 11~35kv or Customized;
Rated L. V.: 0.4kv or Customized;
Impedance Voltage: 4 %;
Cooling Way: Onan/Onaf;
Core Material: Silicon Steel;
Winding Material: Copper/Aluminum;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11/ Yyn0;
Insulation Class: a-Class;
Insulation Media: Mineral Oil as Per IEC 60296;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
AC Withstand Voltage: as Per IEC Standard;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Oil Immersed Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Brand: Pearl;
Type: Oil Immersed Distribution Transformer;
Reference Standards: IEC 60076;
Capacity: 1500kVA;
Rated H. V.: 11~35kV or Customized;
Rated L. V.: 0.4kV or Customized;
Impedance Voltage: 4 %;
Cooling Way: ONAN/ONAF;
Core Material: Silicon Steel;
Winding Material: Copper/Aluminum;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11/ Yyn0;
Insulation Class: a-Class;
Insulation Media: Mineral Oil as Per IEC 60296;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
AC Withstand Voltage: as Per IEC Standard;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Oil Immersed Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Brand: Pearl;
Type: Oil Immersed Distribution Transformer;
Reference Standards: IEC 60076;
Capacity: 6300~63000kVA;
Rated H. V.: 110kVA;
Rated L. V.: 6.3-11kv;
Impedance Voltage: 4 %;
Cooling Way: Onan/Onaf;
Core Material: Silicon Steel;
Winding Material: Copper/Aluminum;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11/ Yyn0;
Insulation Class: a-Class;
Insulation Media: Mineral Oil as Per IEC 60296;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
AC Withstand Voltage: as Per IEC Standard;
|
Application: Power, Power Transmission;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Distribution Transformer, Oil Immersed Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Brand: Pearl;
Type: Oil Immersed Distribution Transformer;
Reference Standards: IEC 60076;
Capacity: 6300~63000kVA;
Rated H. V.: 110kVA;
Rated L. V.: 6.3-11kv;
Impedance Voltage: 4 %;
Cooling Way: Onan/Onaf;
Core Material: Silicon Steel;
Winding Material: Copper/Aluminum;
Temperature Rise (W): 60/65K;
Vector Group: Dyn11/ Yyn0;
Insulation Class: a-Class;
Insulation Media: Mineral Oil as Per IEC 60296;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
AC Withstand Voltage: as Per IEC Standard;
|