Specification |
Type: Ventilator;
Kind: Orthopedics;
Group: People Over 5kg;
LCD Display: Digital Display;
Breathing Mode: Ippv, Sippv, Imv, Simv, Peep, Manu, Sigh and So on;
Tidal Volume Adjustment: 50~1200ml;
Ventilation Capacity Per Minute: ≥18L;
Oxygen Concentration: <45%;
Ventilator Conformance: ≤30ml/Kpa;
Respiratory Rate: 6~60/M;
I/E Ratio: 1:1.5, 1:2.0, 1:2.5, 1:3.0;;
Maximum Safe Pressure: ≤6.0kpa;
|
Type: Anaesthesia Machine;
Kind: Surgical;
Group: Adult;
LCD Display: With LCD Display;
Display: 5.4 Inch TFT Display;
Tidal Volume: Adjustable Range: 50~1500ml;
Ventilation Mode: Ippv,Sippv, Imv, Simv, Manual;
Respiratory Rate: 1~99bpm;
Inspiratory Pressure Trigger Range: ~10~10CMH2o(Electronically Controlled);
Vaporizer Concentration Ranges: 0~5%;
Model No: Jinling-01b Advanced Anesthesia Machine;
Inspiratory/Expiratory (I: E) Ratio: 4:1~1:10;
Back up Power Supply: at Least 4 Hours;
Flowmeter Range: O2: 0.1~10L/Min; N2o: 0.1~10L/Min;
Oxygen Supply Flow Rate: 25~75L/Min;
Sigh: 1 Sigh Breath in Every 80~160 Breaths;
Two Vaporizers: Enflurane, Isoflurane or Sevoflurane;
Gas Supply Pressure: O2: 0.32MPa~0.6MPa; N2o: 0.32MPa~0.6MPa;
Display Range: 0~2000ml;
|
Type: Anaesthesia Machine;
Kind: Surgical;
Group: Adult;
LCD Display: With LCD Display;
Display: LED;
Tidal Volume: Adjustable Range: 50~1500ml;
Ventilation Mode: Ippv,Sippv, Imv, Simv, Manual;
Respiratory Rate: 1~99bpm;
Inspiratory Pressure Trigger Range: ~10~10CMH2o(Electronically Controlled);
Vaporizer Concentration Ranges: 0~5%;
Model No: Jinling 01;
Inspiratory/Expiratory (I: E) Ratio: 4:1~1:10;
Back up Power Supply: at Least 4 Hours;
Display Range: 0~2000ml;
Oxygen Supply Flow Rate: 25~75L/Min;
Single Vaporize: Enflurane, Isoflurane or Sevoflurane;
Sigh: 1 Sigh Breath in Every 80~160 Breaths;
Gas Supply Pressure: O2: 0.32MPa~0.6MPa; N2o: 0.32MPa~0.6MPa;
Flowmeter Range: O2: 0.1~10L/Min; N2o: 0.1~10L/Min;
|
Type: Anaesthesia Machine;
Kind: Surgical;
Group: Adult;
LCD Display: With LCD Display;
Display: LED;
Tidal Volume: Adjustable Range: 50~1500ml;
Ventilation Mode: Ippv,Sippv, Imv, Simv, Manual;
Respiratory Rate: 1~99bpm;
Inspiratory Pressure Trigger Range: ~10~10CMH2o(Electronically Controlled);
Vaporizer Concentration Ranges: 0~5%;
Model No: Jinling 01;
Inspiratory/Expiratory (I: E) Ratio: 4:1~1:10;
Back up Power Supply: at Least 4 Hours;
Display Range: 0~2000ml;
Oxygen Supply Flow Rate: 25~75L/Min;
Single Vaporize: Enflurane, Isoflurane or Sevoflurane;
Sigh: 1 Sigh Breath in Every 80~160 Breaths;
Gas Supply Pressure: O2: 0.32MPa~0.6MPa; N2o: 0.32MPa~0.6MPa;
Flowmeter Range: O2: 0.1~10L/Min; N2o: 0.1~10L/Min;
|
Type: Anaesthesia Machine;
Kind: Surgical;
Group: Adult;
LCD Display: With LCD Display;
Display: 10.4 Inch TFT Display;
Tidal Volume: Adjustable Range: 20~1500ml;
Ventilation Mode: Ippv, Sippv, Vcv, Pcv, Imv, Simv, Manual;
Respiratory Rate: 1~100bpm;
Inspiratory Pressure Trigger Range: ~10~10CMH2o(Electronically Controlled);
Vaporizer Concentration Ranges: 0~5%;
Model No: Jinling-850 Advanced Anesthesia Machine;
Inspiratory/Expiratory (I: E) Ratio: 8: 1~1: 10;
Back up Power Supply: at Least 4 Hours;
Peep Range: 0~20CMH2o (Electronically Controlled);
Sigh: 1 Sigh Breath in Every 80~120 Breaths;
Inhaled Oxygen Concentration Monitor: 21~100%;
Simv Rate: 1~20bpm;
Inspiratory Plateau: 0~1 Second;
Two Vaporizers: Enflurane, Isoflurane or Sevoflurane;
|