Specification |
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Lbs;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Product Name: Outdoor Load Breaker Switch;
Keywords: Outdoor Load Breaker Switch;
Product Model: Fzw32;
Rated Voltage: 40.5kv;
Rated Frequency: 50Hz;
Rated Current: 1250A;
Rated Active Load Breaking Current: 1250A;
Rated Closed-Loop Breaking Current: 1250A;
5% Rated Active Load Breaking Current: 62.5A;
Rated Cable Charging Breaking Current: 25A;
1min Power Frequency Withstand Voltage: 68kv/95kv/110kv;
Lightning Impulse Withstand Voltage: 185kv/215kv;
Rated Short-Circuit Duration: 4s;
Mechanical Life: 10000 Times;
MOQ: 1 Piece;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: RCBO;
Poles Number: 2p 4p;
Type: a/AC;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Voltage: 230/400V AC;
Inc: 6ka;
Tripping Curve: B/C/D;
IP Grade: IP20;
Rated Current: 6-63A;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: RCBO;
Poles Number: 1p+N;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB, RCBO;
Rated Voltage: 240V AC;
Inc: 6/10ka;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: RCBO;
Poles Number: 1p+N;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB, RCBO;
Rated Voltage: 240V AC;
Inc: 6/10ka;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN RAIL;
Structure: MCB;
Poles Number: 1P+N;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Overcurrent Protection;
Standard: IEC60898-1;
Protection Function: Short Circuit Protection, Overload Protection;
Rated insulation voltage: 500V;
Rated operating frequency: 50/60Hz;
Rated ultimate breaking capacity: 4500A;
Rated service breaking capacity: 4500A;
|