Specification |
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Installation: Fixed;
Structure: Vcb;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Product Name: Isolation Handcart;
Keywords: Functional Handcart;
Rated Voltage: 10kv/12kv;
MOQ: Low MOQ;
Sample: Accept;
OEM & ODM Custom: Accept;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: Solar Arrester Surge Protector;
Poles Number: 1p/2p/3p/4p;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection;
Voltage Ui: 500V AC;
ICU: 6ka;
Rated Current (in): 1-63A;
Rated Voltage (Ue): 1p: 240/415V~ 2/3/4p:415V;
Rated Frequency: 50/60Hz;
Energy Limiting Class: 3;
Tripping Curve: B C D;
Electrical and Mechanical Life: 20000;
Standard: IEC60898-1;
Protection Degree: IP20;
Mounting: on DIN Rail 60715 (35mm) by Means of Fast Clip Dev;
Tightening Torque: 2.5n.M;
Storage Temperature: -25~+ 70;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: Solar Arrester Surge Protector;
Poles Number: 1p/2p/3p/4p;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection;
Voltage Ui: 500V AC;
ICU: 6ka;
Rated Current (in): 1-63A;
Rated Voltage (Ue): 1p: 240/415V~ 2/3/4p:415V;
Rated Frequency: 50/60Hz;
Energy Limiting Class: 3;
Tripping Curve: B C D;
Electrical and Mechanical Life: 20000;
Standard: IEC60898-1;
Protection Degree: IP20;
Mounting: on DIN Rail 60715 (35mm) by Means of Fast Clip Dev;
Tightening Torque: 2.5n.M;
Storage Temperature: -25~+ 70;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: Manual Motor Starter;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Current: AC-3 Type Three-Phase;
Control: Button Control or Switch Control;
Standard: En/IEC60947.1/60947.2/60947.4.1;
ICU Breaking Capacity: 30ka;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: RCBO;
Poles Number: 1p+N;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB, RCBO;
Rated Voltage: 240V AC;
Inc: 6/10ka;
|