Specification |
Max Diameter of Workpiece: 900mm;
Mass Scope of Workpiece: <900kg;
Type: Strength Testing Machine;
Maxcapacity: >1000KN;
Accuracy Grade: 1;
Load Way: Electronic Load;
Loading Method: Static Load;
Display: Needle;
Control: Manual Control;
Weight: 0-100Kg;
Power Source: AC 110V/220V at Customized;
Oil Cylinder Position: Under;
Control Mode: Manual;
Transformer Type: Oil, Gas, Dry Is at Customized;
Box Type: 5kVA or Below;
Table Type: 10kVA or Above;
Cabinet Type: 50kVA or Above;
|
After-sales Service: Suppor for Lifelong;
Warranty: 1 Year or Extend;
Type: Transformer Oil Tester;
Display: Digital;
Control: Manual Control;
Weight: About 5.5kg;
Power Source: AC 220 V + 22 V;
Oil Cylinder Position: Top;
Linear Range: 0.001 ~ 0.900 Mgkoh/G;
Correlation Coefficients: 0.999 ~ 0.9998;
Return to Charge Rate: 98 ~ 103%;
Minimum Resolution: 0.001 Mgkoh/G;
Repetitive: 2 ~ 5% (Rsd);
Power Consumption: < 150 W;
Standard: ASTM D974/IEC;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: AC Resonant Test System;
Accuracy Grade: RMS 1.5;
Display: Digital;
Control: Controller or Computer;
Power Source: 220V/380V,10 %Single Phase, 50Hz;
Frequency: 20Hz-300Hz;
Waveform: Sine;
Protection: Over-Current, Over-Voltage,Flash-Over;
Mode: Automatic and Manual Operation Mode;
Print: Support;
Tested Object: Cable, Gis, Transformer, Gil,Ect;
Test Time: 1hours or Customized;
Using Place: Outdoors or Indoors;
Partial Discharge: PC Less Than 10PC Support;
Cabliration Report: Factory Report or The Third -Party Support;
Max Test Voltage: up to 10000kv or Higher;
Max Capacity: up 10000kVA or Higher;
Product Name: AC Resonant Test System;
Calibration: Support Calibration;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: Vlf Hipot Tester;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Capacitive Load;
Display: LCD;
Control: Computer Control;
Weight: 5kgs;
Power Source: AC220V;
Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz;
Stability of Frequency: Fluctuation < 0.5%;
Measurement Accuracy: +-3%;
Positive and Negative Voltage Peak Error: <=3%;
Voltage Waveform Distortion: <=5%;
Product Name: Vlf Hipot Tester;
Test Voltage Range: 30kv/40kv/50kv/60kv/70kv/80kv;
Standard: IEC;
Language: English;
Model: Vlf Hipot Tester with Tan Delta Measuring;
Input Voltage: 220V or 120V;
Frequency: 50Hz/60Hz;
Function1: Vlf Hipot,AC Hipot,DC Hipot, Tan Delat Measuring;
Function 2: Partial Discharge Detect;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: Vlf Hipot Tester;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Capacitive Load;
Display: LCD;
Control: Computer Control;
Weight: 5kgs;
Power Source: AC220V;
Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz;
Stability of Frequency: Fluctuation < 0.5%;
Measurement Accuracy: +-3%;
Positive and Negative Voltage Peak Error: <=3%;
Voltage Waveform Distortion: <=5%;
Product Name: Vlf Hipot Tester;
Test Voltage Range: 30kv/40kv/50kv/60kv/70kv/80kv;
Standard: IEC;
Language: English;
Model: Vlf Hipot Tester with Tan Delta Measuring;
Input Voltage: 220V or 120V;
Frequency: 50Hz/60Hz;
Function1: Vlf Hipot,AC Hipot,DC Hipot, Tan Delat Measuring;
Function 2: Partial Discharge Detect;
|