Specification |
Warranty: 2 Years;
Display: LCD Display;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter;
Electric Equipment: Single-phase;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: Pulse Peak;
Type: Energy Meter;
Customized: Customized;
Measuring Energy Range: 0-99999;
Accuracy Class: 1%;
Normal Voltage: 230V;
Current: 5(40)a;
Voltage Range: 0.8un~1.2un;
Communication: RS-485/Modbus/2-Wire;
Consumption: <2va;
Energy Pulse: 1 Output, Pulse Width(80±20%)Ms;
Rtc Error: ≤0.5s/Day;
IP Degree: Front: IP51;
Operating Temperature: -25ºC~55ºC;
Storage Temperature: -25ºC~70ºC;
Relative Humidity: ≤93%;
|
Warranty: 2years;
Display: LCD;
Installation: Direct Connected;
Usage: Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter;
Electric Equipment: Single-phase;
Theory: Electronic Meter;
Power Meter Connection: Terminal;
Measured Signal: Pulse Peak;
Type: Energy Meter;
Customized: Non-Customized;
Product Name: Singel Phase DIN Rail Energy Meter;
Brand: OEM ODM;
Auxiliary Power Supply: AC 220V;
Reference Frequency: 45~65Hz;
Accuracy: Class 1;
Certificate: IEC 62053-21:2003 CE;
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Display: Analog Signal;
Installation: User Integrated Embedded Installation;
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter, Lightning Monitor/Transmission,Distribution Lines;
Electric Equipment: Single-phase;
Theory: Integrate,Amplify,Convert Electric Signals;
Power Meter Connection: No;
Measured Signal: High Frequency Pulse Current Signals;
Type: Signal Amplifier/Integrator/Converter;
Customized: Customized;
Power Supply: Dual or Single Power Supply;
Power Consumption: 55MW or 15 MW;
Ratio: 1&7 Pin Output 0.5V/Ka; 8 Pin Trigger 1V/100A;
Pulse Bandwidth: >10MHz;
Application 1: Lightning Monitoring;
Application 2: Current Detection of Transmission Lines;
Application 3: Current Detection of Distribution Lines;
Application 4: Power Frequency Steady State Current;
Application 5: Fault Current Detection;
Application 6: Traveling Wave Current Detection;
Application 7: Power Frequency and High Frequency Current;
Installation Type: User Integrated Embedded Installation;
High Frequency Pulse Current Signals: 3/5μs, 8/20μs, 10/ 350μs;
Frequency: up to 10MHz;
Peak Value: 1A to Hundreds of Ka;
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Display: Analog Signal;
Installation: Wall Mounting;
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter, Power Quality Analysis, Fault Current Monitoring;
Electric Equipment: Single-phase;
Theory: Integrate,Amplify,Convert Electric Signals;
Power Meter Connection: Pluggable Terminal;
Measured Signal: 600A-100ka;
Type: Amplifier/Integrator/Converter/Conditioner;
Customized: Customized;
Outer Casing: Compact Shield Aluminium Alloy Enclosure;
Rated Input: 600-100ka;
Rated Output: 5V AC RMS/5V DC(True-RMS)/4-20mA;
Bandwidth: 5Hz to 50kHz(-3dB);
Minimum Current Measurement: 500mA (Ripple 100mA);
Output Ripple Factor: 0.2%;
Response Time: ≤1us;
Power Consumption: 150MW;
Read Accuracy: 0.2% Typical at 1% to 200% Rated Current;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading(1% to 200% of Range);
Current Transducer: Rogowski Coil Y-Fct, Nrc, Zrc;
Application 1: Measuring Devices, Lab Instrumentation;
Application 2: Power Monitoring & Control Systems;
Application 3: Harmonics and Transients Monitoring;
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Display: Analog Signal;
Installation: Wall Mounting;
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Maximum Demand Meter, Power Quality Analysis, Fault Current Monitoring;
Electric Equipment: Single-phase;
Theory: Integrate,Amplify,Convert Electric Signals;
Power Meter Connection: Pluggable Terminal;
Measured Signal: 600A-100ka;
Type: Amplifier/Integrator/Converter/Conditioner;
Customized: Customized;
Outer Casing: Compact Shield Aluminium Alloy Enclosure;
Rated Input: 600-100ka;
Rated Output: 5V AC RMS/5V DC(True-RMS)/4-20mA;
Bandwidth: 5Hz to 50kHz(-3dB);
Minimum Current Measurement: 500mA (Ripple 100mA);
Output Ripple Factor: 0.2%;
Response Time: ≤1us;
Power Consumption: 150MW;
Read Accuracy: 0.2% Typical at 1% to 200% Rated Current;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading(1% to 200% of Range);
Current Transducer: Rogowski Coil Y-Fct, Nrc, Zrc;
Application 1: Measuring Devices, Lab Instrumentation;
Application 2: Power Monitoring & Control Systems;
Application 3: Harmonics and Transients Monitoring;
|