Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: MCB;
Poles Number: 1p/2p/3p/4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Voltage Ui: 1000V;
Imp: 6ka/10ka;
Max Current: 63A;
Tripping Curve: B/C;
Enclosure Box: with/Without;
Rated Current: 6A,10A,16A,20A,32A,40A, 63A;;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Moble No.: Byb1 Series;
Color: Customized;
Type of Trip: Thermal or Magnetic;
Installations: Mounting on 35mm DIN Rail;
Modules: 1;2;3;4;
Paint Finish Customized: Customized;
Ambient Temperature: -5 to 40;
Degree: 20;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3p/4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Operation Voltage: 400/415V;
Standard: IEC60947-2;
Rated Insulation Voltage: 800V;
IR: 10in;
Cat.: a;
Uimp: 8ka;
Ui: 100V;
Rated Current: 250A;
Poles: 3;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Rated Operation Voltage: 400/415V;
Standard: IEC60947-2;
Rated Insulation Voltage: 800V;
IR: 10in;
Cat.: a;
Uimp: 8ka;
Ui: 100V;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Color: Red Hand and White Shell;
APP: Tuya;
Breaker Capacity: 6ka;
Current: 16-100A;
Voltage: 110V/230V/380V;
Hz: 50/60Hz;
Connect Methoed: Bluetooth;
Connect Net: Zigbee;
|