Specification |
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: Ring;
Brand: Shengte;
Rated Capacity: 125kVA;
High Voltage: 10/11kV;
Low Voltage: 0.4kV;
Impedance Voltage: 4%;
No-Load Loss: 0.47kW;
Load Loss: 1.85kW;
No-Load Current: 0.7%;
Frequency: 50/60Hz;
Connection Group: Yyn0/Dyn11;
Insulation Class: F;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Single;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Multi-winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Power Transformer;
Frequency Characteristics: Low Frequency;
Shape of Core: EI;
Brand: Okerda;
Type: Ei Transformer;
Weight: 0.2kg~0.269kg;
Frequency: Low Frequency 50/60Hz;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Single;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Auto-transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Power Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: EE;
Brand: Okerda;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Single;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Separated Winding Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Power Transformer;
Frequency Characteristics: High Frequency;
Shape of Core: EI;
Brand: Okerda;
Transformer Type: High Frequency Transformer;
Woking Frequency: 20kHz-500kHz;
Working Power: 0.5W-1000W;
Working Temperature: -40°-125°;
Storage Temperature: -25°-85°;
Working Moisture: 30-90%;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Brand: Ep Hipot;
Voltage Regulation Range: Can Be Customized;
Control: Electric/Manual;
Insulation Grade: a;
Cooling Oil Number: 25;
Cold Insulation Resistance: 100 Mohm;
Inductive Regulator: Three Phase;
Frequency: 50Hz;
Winding Temperature Rise: 65degree;
Load Voltage: 0-650V at Customized;
Input Voltage: 380V;
Max Load Current: 222A (250kVA 650voutput);
Max Input Current: 457A (250kVA 380vinput);
Keywords: Variac Transformer;
Capacity: Customized;
Input: Customized;
|