Specification |
After-sales Service: 7/24;
Warranty: 1 Year;
|
After-sales Service: Online Training, Reply Customer's Question in 12h;
Warranty: 1 Year;
Description: Vlf-80 Switchgear Busbar Hipot Testing Equipment;
Functions: for Switchgear Busbar Hipot Testing;
Application Field: Electrical Industry, Cable Testing Service;
Test Objects: 10kv, 35kv, 300MW Power Transformer, Cable, etc.;
Features: Portable Switchgear Busbar Hipot Testing Equipment;
Advantages: Smaller, Lighter and Portable;
Max. Voltage Output: 30kv, 50kv, 60kv, 80kv;
Rated Current: 20mA / 30mA;
Measurement Accuracy: 2.5%;
Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz;
Full Set Includes: Controller, Booster(S), Capacitor, Cables;
Power Supply: AC 220V, 50Hz/60Hz;
Delivery Lead Time: 7 Days After The Order Is Confirmed;
Shipping Method: Suggest to Ship by Air or Express;
Trade Terms: EXW, Fob, DDU, CIF, etc.;
|
After-sales Service: Response on Customer's Query Within 8 Hours;
Warranty: One Year;
Description: Sine Wave 300Hz 324kVA Electrical Test Instrument;
Functions: for Cable Withstand Voltage Testing;
Application Field: Electrical Industry, Cable Testing Service;
Test Objects: 10kv, 35kv, 300MW Power Transformer, Cable, etc.;
Features: Sine Wave 300Hz 324kVA Electrical Test Instrument;
Advantages: Smaller, Lighter and Portable;
Max. Voltage Output: 30kv, 50kv, 60kv, 80kv;
Rated Current: 20mA / 30mA;
Measurement Accuracy: 2.5%;
Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz;
Full Set Includes: Controller, Booster(S), Capacitor, Cables;
Power Supply: AC 220V, 50Hz/60Hz;
Delivery Lead Time: 7 Days After The Order Is Confirmed;
Shipping Method: Suggest to Ship by Air or Express;
Trade Terms: EXW, Fob, DDU, CIF, etc.;
|
After-sales Service: Response on Customers' Questions Within 12 Hours.;
Warranty: 12 Months;
Description: 3 Phase Transformer Test Turn Ratio Test Set;
Functions: Test Turns Ratio and Group Vector of Transformer;
Application Field: Electrical Industry, Transformer Manufacturer;
Features: 7kg Weight 3 Phase Transformer Turn Ratio Test Set;
Reference Standards: IEC76-1 and IEC60044;
Ratio Measurement Range: 1-10000;
Group Measurement: 1-12;
Max. Test Timestest Voltage: AC 0~80V Continuously, Frequency 50Hz;
Dimension: 400mm*350mm*200 mm;
Weight: 8kg;
Power Supply: AC 220V, 50Hz/60Hz;
Delivery Lead Time: 7 Days After The Order Is Confirmed;
Shipping Method: Suggest to Ship by Air or Express;
Trade Terms: EXW, Fob, DDU, Cit, etc.;
Payment Term: 30% as Deposit, The Balance Before Delivery;
|
After-sales Service: Online Training, Reply Customer's Question in 12h;
Warranty: 365 Days;
Description: Electrical Power Transformer 10kv Tan Delta Tester;
Functions: Measure Electrical Loss Tangent and Capacitance;
Application Field: Electrical Industry, Transformer Manufacturer;
Features: Multifunctional Transformer 10kv Tan Delta Tester;
Output Voltage: 10kv or 12kv;
Output Max. Current: 200mA;
Output Capacity: 2000va;
Self-Excited Power: AC 0V-50V/15A;
Dimension: 350mm*270mm*270mm;
Weight: 28kg;
Power Supply: AC 220V, 50Hz;
Delivery Lead Time: 7 Days After The Order Is Confirmed;
Shipping Method: Suggest to Ship by Air or Express;
Trade Terms: EXW, Fob, DDU, Cit, etc.;
Payment Term: 30% as Deposit, The Balance Before Delivery;
|