Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1p/2p/3p/4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Current: 63A;
Voltage Ui: 1000V;
Rated Insulation Voltage: 1200V;
Ingress Protection: IP40; Wiring Port IP20;
Overvoltage Category: III;
Pollution Degree: 3;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: ICE60898-1, GB10963-1;
Rated curret (In): 1-63A;
Trip curve: B, C, D;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 230V ; 2/3/4P: 400V;
Rated Current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A,25A, 32A, 40A, 5;
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated breaking capacity (Icn): 10kA;
Rated operating short circuit breaking c: 7.5kA;
Electrical life: 4000;
Pollution degree: 3;
Mechanical life: 20000;
Protection degree: IP20;
Insultation Voltage (Ui): 500V;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: ICE60947-1, GB14048-2;
Rated curret (In): 6A, 10A, 16A, 20A,25A, 32A,40A,50A,63A;
Trip curve: B, C, D;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 230V ; 2/3/4P: 500V;
Rated Current: 32A;
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated breaking capacity (Icn): 6kA;
Rated operating short circuit breaking c: 6kA;
Electrical life: 20000;
Pollution degree: 3;
Mechanical life: 20000;
Protection degree: IP20;
Insultation Voltage (Ui): 500V;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Drawer/ Fixed Type;
Structure: ACB;
Poles Number: 3p 4p;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection, Overcurrent Protection;
Term: Fob/CIF/CIP;
Available Service: OEM,ODM;
Delivery: by Sea / by Train / by Air;
Warranty: 12 Months;
Frame Current: 630A-6300A;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Drawer/ Fixed Type;
Structure: ACB;
Poles Number: 3p 4p;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection, Overcurrent Protection;
Term: Fob/CIF/CIP;
Available Service: OEM,ODM;
Delivery: by Sea / by Train / by Air;
Warranty: 12 Months;
Frame Current: 630A-6300A;
|