Specification |
Classification: Imaging Diagnostic Equipment;
Type: Ultrasound Scanner;
Group: All People;
Product Type: Sun-906A High Quality 3D Color-Doppler Ultrasound;
Display: 15" LED;
Application: Ob, Gyn, Cardiac, Vascular, Urology, Small Parts;
Imaging Modes: B, 2b, 4b, M, B/M, B/C, Cfm, Pdi, Pw, Duplex/Tripl;
Battery: Yes, Li-ion;
USB Ports: 2;
Hard Disc: 64GB (SSD), 120g/200GB SSD (Optional);
Dicom Connectivity: Dicom 3.0;
Equipment Weight: 5.5kg;
Equipment Dimension: 365mm*300mm*75mm;
Cine Review Speed: 1, 2, 4, 8;
Cine Memory: 1200 Frame;
Cine Review Loop: Yes;
Cine Capture Function: Yes;
Storage Format: PNG, AVI, BMP, JPEG, Dicom;
|
Classification: Physiological Functions of Diagnosis and Monitoring Equipment;
Product Name: Fully Auto Chemistry Analyzer;
Throughput: 300tests/Hour,ISE(Optional);
System: Optional Open or Close System,Continuous Working F;
Sample Positions: 49sample Positions;
Reagent Position: 56 Reagent Positions;
Sample Volume: 2-70UL;
Reagent Volume: 20-350UL;
Probe: with Anti-Collision Function,Liquid Level Detectio;
Probe Washing: Utomatic Washing Interior and Exterior;
Reagent Cooling: 2~12ºC for 24 Hours;
Water Consumption: Deionized Water<5L/H;
Humidity: 40~85%;
Interface: LAN Port Access;
Lis System: Bi-Direction,Support Hl7 Protocol;
Software: Windows 7/8/10,32or 64bit;
|
Classification: Biological Diagnostics;
Type: Electrolyte Analyzer;
Group: All;
Sample: Serum, Plasma, Whole Blood, Cerebrospinal Fluid an;
Measuring Speed: ≤25s;
Analysis Method: Ion Selective Electrode (ISE);
Sample Volume: 60~150μl;
Storage: up to 50,000 Test Results;
Printer: Build-in Thermal Printer;
Interface: RS232 Port for Lis;
Display: 7-Inch High-Definition Touch Screen;
Language: Chinese and English, Other Languages Can Be Custom;
Calibration: Automatic and Manual Calibration;
Other Function: Sample Volume Detection;
Power Supply: AC100~240V, 50/60Hz, 70va;
|
Classification: Karl Fischer Titrator;
Type: Karl Fischer Titrator;
Group: All;
Range: 0.1mg~250mg;
Resolution: 0.1mg;
Polarization Current Accuracy: 1μa±0.2μa; 50μa±10μa;
Repeatability: ±0.5%;
Power Supply: 110~220V, 50/60Hz;
External Size(mm): 340*400*400;
Packing Size (mm): 540*490*480;
Net/Gross Weight (Kg): 10/12;
|
Classification: Imaging Diagnostic Equipment;
Type: Fully Auto Elisa Processor;
Group: All;
Model: Biobase 2000;
Sample Racks: 552 Sample Positions(Tubes 13mm);
Pipetting: 8~1000UL;
Dispensing System: 2 Aspirating-Dispensing Probe with X-Y-Z Movement;;
Reagent Racks: 23reagent Racks, Editable;
Pipetting Range: 8~1000UL,1UL Stepping;
Dispensingtime: 4 Minutesto Whole 96well Microplates;
Incubation: 2 Independent Incubators;
Temperature Range: Rt to 45 °c;
Washing Probes: Two Line 8-Nozzle Manifolds;
Wash Containers: 2 Wash Buffers 2L, 1 Distilled Water, 1 Waste Wate;
Washing Residual: <2μl;
Software: Windows 7;
Lis System: Bi-Direction,Support Hl7 Protocol;
Results: Absorbance and Results Reviewable by Software;
|