Specification |
After-sales Service: Maintenance & Refund;
Warranty: 1 Year;
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil;
Size: DN 8 - DN 40;
Sensor: Thread / Flange / Clamp on;
Application: Industrial Production;
Type: Volume Type Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Positive Displacement Flowmeter;
Measurement Object: Closed Pipeline;
Line Size: 6mm-40mm;
Working Temperature: -196 - 170 Deg.C;
Working Pressure: up to 45 MPa;
Housing Material: Ss 304, Ss 316L, Aluminum Alloy, PTFE;
Gear Material: Ss 304, Ss 316L, Aluminum Alloy, PTFE;
Relative Humidity: 5% -95%;
Power Supply: DC18-24V;
Protection Level: IP 65;
Ambient Temperature: -20 - 55 Deg.C;
Ambient Pressure: 86 -106 Kpa;
Signal Output: Pulse,4-20mA, RS 485;
Signal Transmission Distance: 1,000m;
Display: No and LCD Display;
Connection: Flange, Thread, Tri-Clamp on,Swagelok Connection;
Max Pressure. Bar: 1.6 MPa, 5.0 MPa Customized;
|
Accuracy: >±1%;
Main Application: Oxygen;
Size: < DN5;
Application: Oxygen Reducing;
Type: Impact Flow Meter;
Measuring Media: Gas;
Measuring Principle: Mechanics;
Measurement Object: Closed Pipeline;
Input Pressure: 4000psi;
Output Pressure: 0-6bar;
Range of Flow: 2-15L/Min;
Connection Thread: as Your Requirment;
Humidifier Bottle: 200ml;
|
Accuracy: >±1%;
Main Application: Oxygen;
Size: < DN5;
Application: Oxygen Reducing;
Type: Impact Flow Meter;
Measuring Media: Gas;
Measuring Principle: Mechanics;
Measurement Object: Closed Pipeline;
Input Pressure: 4000psi;
Output Pressure: 0-6bar;
Range of Flow: 2-15L/Min;
Connection Thread: as Your Requirment;
Humidifier Bottle: 200ml;
|
Accuracy: 1G 1.5G 2.5G;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Aqueous Alkali;
Size: 15, 20,25 etc;
Sensor: Clamp-on/External;
Application: Industrial Production;
Type: Vortex Flow Meter;
Measuring Media: Fluid, Gas, Steam;
Measuring Principle: Electrical Principles;
Measurement Object: Open Channel;
Aperture Diameter: 15, 20,25 etc;
Accuracy Grade: 1G;
Medium Temperature: -40~330ºC;
Supply: Sensor: DC +12V, DC +24V;
Output: high level≥5V, low level≤1V;
Measuring Flow Velocity: Less than 20m/s;
Range Rate: 1:6~1:30;
|
Accuracy: 0.5G;
Main Application: Water, Wastewater, Aqueous Alkali;
Size: DN10~DN150;
Sensor: Tube/Flange;
Application: Fluid;
Type: Rotameter Float Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Open Channel;
Aperture Diameter: DN10-DN150;
Accuracy Grade: 1.5G;
Cable Interface: M20×1.5;
Supply: 24VDC;
Output: 4~20mA;
Output Load: 500 Ω (24V Power Supply);
Ingress Protection: IP65;
|