Specification |
After-sales Service: Maintenance & Refund;
Warranty: 1 Year;
Accuracy: ±0.2-0.5%;
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas;
Size: DN50-100;
Sensor: Portable Fuel Flow Meter;
Application: Industrial Production;
Type: Turbine Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Portable Fuel Flow Meter;
Measurement Object: Closed Pipeline;
Line Size: 4mm-200mm;
Working Temperature: -20 - 120 Deg.C;
Working Pressure: up to 42 MPa;
Housing Material: Ss 304, Ss 316L;
Rotor Material: 2Cr13 Stainless Steel, Alloy CD4MCU;
Relative Humidity: 5% -95%;
Power Supply: DC12-24V, 3.6V Lithium Battery;
Protection Level: IP 65;
Ambient Temperature: -20 - 55 Deg.C;
Ambient Pressure: 86 -106 Kpa;
Signal Output: Pulse,4-20mA, RS 485;
Signal Transmission Distance: 1,000m;
Display: Mechanical and Digital Display;
Connection: Flange, Thread, Tri-Clamp on;
Explosion Proof: Exdii Bt 6, Exiaii CT4;
|
After-sales Service: 24 Hours;
Warranty: One Year;
Accuracy: ±2mm;
Main Application: Water;
Size: Radar Level Sensor;
Sensor: Clamp-on/External;
Application: Water;
Type: Radar Level Meter;
Measuring Media: Liquid;
Measuring Principle: Radar;
Measurement Object: Open Channel;
Name: Radar Level Meter;
Power Supply: 7-24V DC;
Radar Frequency: 24GHz;
Operating Temperature: -30~80ºC;
Measuring Range: 0.2-10m(OEM 20m/30m/40m);
|
After-sales Service: 24 Hours;
Warranty: One Year;
Accuracy: ±2mm;
Main Application: Water;
Size: Radar Level Sensor;
Sensor: Clamp-on/External;
Application: Water;
Type: Radar Level Meter;
Measuring Media: Liquid;
Measuring Principle: Radar;
Measurement Object: Open Channel;
Name: Radar Level Meter;
Power Supply: 7-24V DC;
Radar Frequency: 24GHz;
Operating Temperature: -30~80ºC;
Measuring Range: 0.2-10m(OEM 20m/30m/40m);
|
Accuracy: ±0.2-0.5%;
Main Application: Water;
Size: DN10-500;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Power Supply: 220V/24V/Battery;
Signal Output: 4-20mA; Pulse;
Supply Voltage: 110/220VAC ; 24VDC +10%;
Compact Type: IP65;
Body Material: Carbon Steel;
Nominal Pressure: 1.0~4.0MPa;
|
Accuracy: 0.1%-0.5%;
Main Application: Water;
Sensor: Tube/Flange;
Application: Industrial Production;
Type: Electromagnetic Flow Meter;
Measuring Media: Liquid;
Measuring Principle: Electrical Principles;
Measurement Object: Closed Pipeline;
Signal Output: 4-20mA DC, Intelligent Hart Fieldbus Protocol Sign;
Compact Type: IP65;
Nominal Pressure: 1.0~4.0MPa;
Diaphragm Material: 316L, Hastelloy,Tan,Petf;
Capillary Length: 1-10m;
|