Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Insert;
Structure: MCB;
Poles Number: 1p,2p,3p,4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Poles: 1,2,3,4;
Rated Voltage: Single-Phase AC230V, 50/60Hz; Three-Phase AC440V;
Rated Current: 0~63A, 100A;
Residual Operating Current: 0-500mA Can Be Set Freely;
Short Circuit Breaking Capacity: Icn=Lcs=6ka;
Mechanical Life: More Than 20000 Times;
Electrical Life: More Than 6000 Times;
Action Time: Leakage Action Less Than 100ms; Closing Time Is Le;
Protection Grade: IP20;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: MCB;
Poles Number: 1p/2p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Voltage: 100V/200V;
Imp: 10ka;
Rated Current: 63A/80A/100A/125A;
Tripping Curve: B/C;
Enclosure Box: with/Without;
IP Grade: IP20;
Tripping Capacity: 10ka;
Mounting Type: DIN Rail;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN RAIL;
Structure: MCB;
Poles Number: 1P 2P 3P 4P 1P+N 3P+N;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Overcurrent Protection;
Standard: IEC60898-1;
Protection Function: Short Circuit Protection, Overload Protection;
Rated insulation voltage: 500V;
Rated operating frequency: 50/60Hz;
Rated ultimate breaking capacity: 6000A;
Rated service breaking capacity: 6000A;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: ELCB;
Poles Number: 2p ,4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Overcurrent Protection;
Poles: 1p,2p, 3p+N,4p;
Frequency: 50/60Hz;
Rated Current in(a): 10,16, 20,25, 32,40, 63A;
Rated Residual Operating Current: 0.03,0.1,0.3A;
Rated Working Voltage Ue(V): 250/500V;
Breaking Capacity(a): 6ka;
Rated Limiting Short-Circuit Current: 10000A;
Mechanical Life(Times): 20000times;
Electric Life: 6000times;
Bcd Cure: C;
International Certification: CCC/CB;
Standard: IEC60898-1 GB/T 0963.1;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: RCCB;
Poles Number: 2p ,4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Overcurrent Protection;
Poles: 2pole, 4pole;
Frequency: 50/60Hz;
Rated Current in(a): 16, 20,25, 32,40, 50,63A;
Rated Residual Operating Current: 0.03,0.1,0.3A;
Rated Working Voltage Ue(V): 230/400V;
Breaking Capacity(a): 4.5ka;
Limiting Value of Un-Operating Current: 6in;
Rated Limiting Short-Circuit Current: 10000A;
Mechanical Life(Times): 20000times;
Electric Life: 4000times;
Bcd Curve: C;
|