Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Poles: 1,2,3,4;
Model No.: Ycb6h;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Structure: MCB;
Poles Number: 4, DIN Rail Mounting;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), Mini, Lighting "C"or Motor"D";
Protection: Overload and Short Circuit;
Rated Current: 6AMP;
Standard: IEC60898;
Pole: 4;
Rated Voltage: 220/380VAC;
Case Material: PA66;
OEM: Avaiable;
Keyword: Circuit Breaker;
Keyword2: Miniature Circuit Breaker;
Keyword3: MCB;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Structure: MCB;
Poles Number: 4, DIN Rail Mounting;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), Mini, Lighting "C"or Motor"D";
Protection: Overload and Short Circuit;
Rated Current: 6AMP;
Standard: IEC60898;
Pole: 4;
Rated Voltage: 220/380VAC;
Case Material: PA66;
OEM: Avaiable;
Keyword: Circuit Breaker;
Keyword2: Miniature Circuit Breaker;
Keyword3: MCB;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail Mounting;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Key Word: MCCB;
Key Word2: Moulded Case Circuit Breaker;
Key Word3: Circuit Breaker;
Rated Voltage: 400V, 230/400V AC;
Rated Frequency: 50/60Hz;
Breaking Capacity1: 65ka;
OEM: Available;
Material: PC;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail Mounting;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Key Word: MCCB;
Key Word2: Moulded Case Circuit Breaker;
Key Word3: Circuit Breaker;
Rated Voltage: 400V, 230/400V AC;
Rated Frequency: 50/60Hz;
Breaking Capacity1: 65ka;
OEM: Available;
Material: PC;
|