Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Standard: IEC/En 60947-2;
Electrical Life (Times): 10000;
Mechanical Life (Times): 20000;
Rated Operational Voltage(Ue): DC 250V,500V,750V,1000V;
Number of Poles: 1p, 2p, 3p, 4p;
Rated Current in(a): 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63, 80;
Accessory: Shunt Release, Under Voltage Release;
|
Breaking Capacity: 4.5ka;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN-Rail Mounting;
Type: RCBO;
Function: RCBO;
Modelnumber: Hdb2le-63;
Leakage Protection Mode: AC Type;
Single Gross Weight: 1.000kg;
Selling Units: Single Item;
Mounting Type: Rail Mounting;
Rated Voltage: 230V;
Bcd Curve: C;
IP Level: IP20;
Mounting: DIN Rail35mm;
Rated Frequency (Hz): 50;
Packing: Carton Box;
Color: Blue and White;
Protection: Lsig;
Single Package Size: 4X14X10cm;
Pole: 1p+N;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Conventional Circuit Breaker;
Poles Number: 3;
Type: Circuit Breaker;
Function: Overcurrent Protection~@~Circuit-Breaker Failure P;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Energy-storage Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Vcb;
Poles Number: 3;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Model: Zw32-S;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: IEC 60898-1 & GB 10963.1;
Rated curret (In): 1A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A;
Trip curve: B, C, D;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 240V/415V ; 2/3/4P: 415V;
Insulation voltage(Ui): 500V;
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated breaking capacity (Icn): 10kA;
Rated operating short circuit breaking c: 7.5kA;
Rated impulse withstand voltage (Uimp): 4kA;
Electrical life: 4000;
Pollution degree: 3;
Mechanical life: 20000;
Protection degree: IP20;
|