Fire Alarm Valve
US$50.00-179.00 / Piece
View
  • Recommend for you
  • What is Medium Velocity Water Spray Nozzle for Fire Fighting
  • What is Quick Response K115 Upright Pendent Sidewall Sprinkler
  • What is Water Curtain Nozzle Fire Sprinkler Spray Nozzle

What is Fire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection System

About this Item
Details
Company Profile

Price

Min. Order Reference FOB Price

1 Piece US$50.00-179.00 / Piece

Sepcifications

  • Sprinkler Head Type Closed
  • Alarm Valve Type Wet Alarm Valve
  • Automatically Opened and Closed Repeatedly Can′t Automatically Opened and Closed
  • Closed Fire Sprinkler System Wet Fire Sprinkler System
  • Wet Alarm Valve Structure Seat Type
  • Alarm Valve Diameter 80mm-250mm
  • Transport Package Standard Export Package
  • Specification 3"-10"
  • Trademark SINCO/OEM
  • Origin Quanzhou, Fujian
  • Finished Red Painting
  • Size 3"/4"/5"/6"/8"/10"
  • Working Pressure 1.6MPa
  • Connection Flange
  • Accessories Retard Chamber, Water Motor Gong, etc.

Product Description

Fire Alarm Check Valve for Automatic Fire Sprinkler Fire Protection System Introduction Alarm Check Valve is core element in wet pipe fire sprinkler systems. It serves a dual purpose which prevents a reverse flow of water (non-return), also provides for the use of the water motor gong. ...

Learn More

Fire Alarm Valve Comparison
Transaction Info
Price US $ 50.00-179.00/ Piece US $ 0.50-0.70/ Piece US $ 0.50-0.70/ Piece US $ 100.00-10,000.00/ Piece US $ 100.00-10,000.00/ Piece
Min Order 1 Pieces 500 Pieces 500 Pieces 1 Pieces 1 Pieces
Trade Terms - - - - -
Payment Terms L/C, T/T, D/P, Western Union, Paypal T/T T/T L/C, D/P, Western Union, Paypal, Money Gram L/C, D/P, Western Union, Paypal, Money Gram
Quality Control
Management System Certification ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, ISO 14064, GMP, BSCI, BS 25999-2, ISO 13485, ANSI/ESD, ISO 29001, ISO 50001, PAS 28000, ISO 10012, ISO 17025 - - - -
Trade Capacity
Export Markets North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe North America, South America, Europe, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Domestic North America, South America, Europe, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Domestic Southeast Asia/ Mideast, Domestic Southeast Asia/ Mideast, Domestic
Annual Export Revenue - - - - -
Business Model OEM, ODM, Own Brand OEM, ODM, Own Brand OEM, ODM, Own Brand OEM, ODM, Own Brand OEM, ODM, Own Brand
Average Lead Time Off-season: within 15 Day(s)
Peak-season: 1-3 Month(s)
Off-season: 1 Month(s)
Peak-season: within 15 Day(s)
Off-season: 1 Month(s)
Peak-season: within 15 Day(s)
- -
Product Attributes
Specification
Sprinkler Head Type: Closed;
Alarm Valve Type: Wet Alarm Valve;
Automatically Opened and Closed Repeatedly: Can't Automatically Opened and Closed;
Closed Fire Sprinkler System: Wet Fire Sprinkler System;
Wet Alarm Valve Structure: Seat Type;
Alarm Valve Diameter: 80mm-250mm;
Finished: Red Painting;
Size: 3"/4"/5"/6"/8"/10";
Working Pressure: 1.6MPa;
Connection: Flange;
Accessories: Retard Chamber, Water Motor Gong, etc.;
Sprinkler Installation: Pendent;
Sprinkler Head Type: Open;
Alarm Valve Type: Wet Alarm Valve;
Automatically Opened and Closed Repeatedly: Can Automatically Opened and Closed;
Open Fire Sprinkler System Type: Deluge System;
Closed Fire Sprinkler System: Preaction Fire Sprinkler System;
Dry Alarm Valve Type: Differential Type;
Wet Alarm Valve Structure: Butterfly Valve Type;
Alarm Valve Diameter: 50mm;
Nozzle Flow Coefficient: 161;
Deluge Valve Type: Double Disc Type;
Type: Upright/Pendent;
Connecting Thread: R3/4(K=161);
Sensitive Element: Fusible Alloy;
Temp. Rating: 74°c;
Sprinkler Installation: Upright;
Sprinkler Head Type: Open;
Alarm Valve Type: Wet Alarm Valve;
Automatically Opened and Closed Repeatedly: Can Automatically Opened and Closed;
Open Fire Sprinkler System Type: Deluge System;
Closed Fire Sprinkler System: Preaction Fire Sprinkler System;
Dry Alarm Valve Type: Differential Type;
Wet Alarm Valve Structure: Butterfly Valve Type;
Alarm Valve Diameter: 50mm;
Nozzle Flow Coefficient: 80;
Deluge Valve Type: Double Disc Type;
Type: Upright/Pendent;
Connecting Thread: R1/2(K=80) / R3/4(K=115);
Glass Bulb: 3 mm;
Glass Bulb Color: Orange/Red/Yellow/Green/Blue;
Sprinkler Installation: Pendent;
Sprinkler Head Type: Open;
Alarm Valve Type: Wet Alarm Valve;
Automatically Opened and Closed Repeatedly: Can Automatically Opened and Closed;
Open Fire Sprinkler System Type: Deluge System;
Closed Fire Sprinkler System: Wet Fire Sprinkler System;
Nominal Pressure: 1.6/2.5MPa;
Hydraulic Friction: ≤0.07MPa;
Nominal Diameter: DN100;
Material: Cast Iron and Stainless Steel;
Connector Type: Flange and Groove Type;
Sprinkler Installation: Pendent;
Sprinkler Head Type: Open;
Alarm Valve Type: Wet Alarm Valve;
Automatically Opened and Closed Repeatedly: Can Automatically Opened and Closed;
Open Fire Sprinkler System Type: Deluge System;
Closed Fire Sprinkler System: Wet Fire Sprinkler System;
Nominal Pressure: 1.6/2.5MPa;
Hydraulic Friction: ≤0.07MPa;
Nominal Diameter: DN80;
Material: Cast Iron and Stainless Steel;
Connector Type: Flange and Groove Type;
Supplier Name

SINCO FIRE AND SECURITY CO., LIMITED

China Supplier - Diamond Member Audited Supplier

Ca Fire Protection Co., Ltd.

China Supplier - Gold Member Audited Supplier

Ca Fire Protection Co., Ltd.

China Supplier - Gold Member Audited Supplier

Guangdong Yingsui Fire Fighting Equipment Co., Ltd.

China Supplier - Gold Member Audited Supplier

Guangdong Yingsui Fire Fighting Equipment Co., Ltd.

China Supplier - Gold Member Audited Supplier