Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 2;
Type: Earth Leakage;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Standard: IEC60947-2;
Material: PA66;
Rated Voltage: 230/400V;
Mechanical Life: 10000 Times;
Rated Current: 63A 80A 100A;
Certificate: CE/ISO9001;
Product Name: RCBO;
Rated Frequency: 50/60 Hz;
Color: White;
Keywords: RCBO;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: MCCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Service: 24 Hours Online Service;
Delivery Time: 2-3 Days;
MOQ: 1PC;
Provide Technical Support: Yes;
Shipping Method: DHL UPS FedEx TNT EMS;
Protection Level: IP65;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: MCCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Service: 24 Hours Online Service;
Delivery Time: 2-3 Days;
MOQ: 1PC;
Provide Technical Support: Yes;
Shipping Method: DHL UPS FedEx TNT EMS;
Protection Level: IP65;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Conventional Circuit Breaker;
Poles Number: 3;
Type: Circuit Breaker;
Function: Overcurrent Protection, Circuit-Breaker Failure P;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 2;
Type: Circuit Breaker;
Function: Overcurrent Protection;
Standard: ICE60947-2, GB14048-2;
Rated curret (In): 80A,100A,125A;
Trip curve: B, C, D;
Pole: 1P ,2P, 3P, 4P;
Rate voltage (Ue): 1P: 230V ; 2/3/4P: 400V;
Insulation voltage(Ui): 500V;
Rated frequency: 50/60Hz;
Energy limiting class: 3;
Rated breaking capacity (Icn): 10kA;
Rated operating short circuit breaking c: 7.5kA;
Rated impulse withstand voltage (Uimp): 4kA;
Electrical life: 4000;
Pollution degree: 3;
Mechanical life: 20000;
Protection degree: IP20;
|