Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 2;
Type: Earth Leakage;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Standard: IEC60947-2;
Material: PA66;
Rated Voltage: 230/400V;
Mechanical Life: 10000 Times;
Rated Current: 63A 80A 100A;
Certificate: CE/ISO9001;
Product Name: RCBO;
Rated Frequency: 50/60 Hz;
Color: White;
Keywords: RCBO;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Remote Operate by Smart Phone;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: ELCB;
Poles Number: 4;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, Metering;
Color: Black Hand and White Shell;
APP: Tuya;
Breaker Capacity: 6ka;
Current: 16-100A;
Voltage: 380V;
Hz: 50/60Hz;
Connect Methoed: Bluetooth;
Connect Net: Zigbee;
Material: PA66;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Oil-immersed Type;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Usage Category: Category a;
Mechanical Life(Time): 4000;
Electrical Life(Time): 1000;
Arcing Distance: <100;
Rated Insulation Voltage Ui (V): 1000V;
Rated Impulse Withstandvoltage Uimp (V): 12kv;
Rated Working Voltage Ue (V): 400V 690V;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCCB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Usage Category: Category a;
Mechanical Life(Time): 2500;
Electrical Life(Time): 500;
Arcing Distance: <100;
Rated Insulation Voltage Ui (V): 1000V;
Rated Impulse Withstandvoltage Uimp (V): 12kv;
Rated Working Voltage Ue (V): 400V 690V;
|