Specification |
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Vcb;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Voltage: 12kv;
Installation Method: Withdrawable;
Rated Current: 630A/1250A/1600A/2000A;
Phase Distance: 150mm/210mm;
Rated Frequency: 50/60Hz;
Material: Steel, Expoxy Resin;
Customize: Yes;
Model No.: Zn63-12 Beside Type;
Size: Medium;
Mechanical Life: 1000times;
Closing Time: 0.1s;
Seismic Intensity: Not Exceeding Level 8;
Average Closing Speed: 0.4~0.8m/S;
Ambient Temperature: -15-40;
Altitude: ≤1000m;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Structure: MCB;
Poles Number: 4;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), Mini, Lighting "C"or Motor"D";
Protection: Overload and Short Circuit;
Rated Current: 6AMP;
Standard: IEC60898;
Pole: 4;
Rated Voltage: 220/380VAC;
Case Material: PA66;
OEM: Avaiable;
Keyword: Circuit Breaker;
Keyword2: Miniature Circuit Breaker;
Keyword3: MCB;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Structure: MCB;
Poles Number: 4;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), Mini, Lighting "C"or Motor"D";
Protection: Overload and Short Circuit;
Rated Current: 6AMP;
Standard: IEC60898;
Pole: 4;
Rated Voltage: 220/380VAC;
Case Material: PA66;
OEM: Avaiable;
Keyword: Circuit Breaker;
Keyword2: Miniature Circuit Breaker;
Keyword3: MCB;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Structure: MCB;
Poles Number: 4;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), Mini, Lighting "C"or Motor"D";
Protection: Overload and Short Circuit;
Rated Current: 6AMP;
Standard: IEC60898;
Pole: 4;
Rated Voltage: 220/380VAC;
Case Material: PA66;
OEM: Avaiable;
Keyword: Circuit Breaker;
Keyword2: Miniature Circuit Breaker;
Keyword3: MCB;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Structure: MCB;
Poles Number: 4;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), Mini, Lighting "C"or Motor"D";
Protection: Overload and Short Circuit;
Rated Current: 6AMP;
Standard: IEC60898;
Pole: 4;
Rated Voltage: 220/380VAC;
Case Material: PA66;
OEM: Avaiable;
Keyword: Circuit Breaker;
Keyword2: Miniature Circuit Breaker;
Keyword3: MCB;
|