Specification |
Task: Industrial Automation;
Structure: Combination;
Mathematical Model: Data Collection;
Signal: Continuous;
Function: Automatic Control, Monitoring, Measurement, Cloud Server;
Condition: New;
Customized: Customized;
Material: Polycarbonate Nylon 6.6;
Operating System: Linux;
Input Voltage (Field): 24 VDC;
Ethernet Ports: 2 X RJ45;
Max Cable Length: 100m;
Baud Rate: 10/100 Mbit/S;
Isolation Protection: ESD Contact: 8kv, Surge: 4kv(10/1000us);
CPU: 300MHz;
RAM: 64MB;
Flash: 128MB;
I/O Modules: Max 32;
Signal Type: DIN, AIN, DO, AO, RS485, RS232, Relay;
Protection Type: IP20;
Installation Method: DIN-35 Rail;
EMC: En 55022: 2006/A1: 2007 (CE &Re) Class B;
|
Task: Program;
Structure: Closed-Loop;
Mathematical Model: Linear;
Signal: Continuous;
Function: Automatic Control, Protection, Monitoring, Measurement;
Condition: New;
Customized: Customized;
Material: ABS;
Phase: Three Phase;
Rated Voltage: 380V-415V;
Rated Power: 0.75-4kw;
Operational Mode: Automatic and Manual;
Control Mode: Time Setting/Water Level/Pressure/Water Supply...;
Controlled Pumps: Single Pump;
Display: LCD;
Applications: Motor and Pump Control and Protection;
|
Task: Program;
Structure: Closed-Loop;
Mathematical Model: Linear;
Signal: Continuous;
Function: Automatic Control, Protection, Monitoring, Measurement;
Condition: New;
Customized: Customized;
Material: Stainless Steel;
Phase: Three Phase;
Rated Voltage: 380V-415V;
Rated Power: 1.1-11kw;
Operational Mode: Automatic and Manual;
Control Mode: Time Setting/Water Level/Pressure/Water Supply...;
Controlled Pumps: Single Pump;
Display: LCD;
Applications: Motor and Pump Control and Protection;
|
Task: Program;
Structure: Closed-Loop;
Mathematical Model: Linear;
Signal: Continuous;
Function: Automatic Control, Protection, Monitoring, Measurement;
Condition: New;
Customized: Customized;
Material: ABS;
Phase: Three Phase;
Rated Voltage: 380V-415V;
Rated Power: 1.1-7.5kw;
Operational Mode: Automatic and Manual;
Control Mode: Time Setting/Water Level/Pressure/Water Supply...;
Controlled Pumps: Single Pump;
Display: LCD;
Applications: Motor and Pump Control and Protection;
|
Task: Program;
Structure: Closed-Loop;
Mathematical Model: Linear;
Signal: Continuous;
Function: Automatic Control, Protection, Monitoring, Measurement;
Condition: New;
Customized: Customized;
Material: ABS;
Phase: Three Phase;
Rated Voltage: 380V-415V;
Rated Power: 1.1-11kw;
Operational Mode: Automatic and Manual;
Control Mode: Time Setting/Water Level/Pressure/Water Supply...;
Controlled Pumps: Single Pump;
Display: LCD;
Applications: Motor and Pump Control and Protection;
|