Specification |
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Single;
Usage: Single-Phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer, Current, Power and Energy Monitoring D;
Core: Amorphous Alloy Transformer;
Cooling Method: Dry-Type Transformer;
Winding Type: Multi-Winding Transformer;
Frequency Characteristics: 50 to 400 Hz;
Brand: Grewin;
Shape of Core: PBT Resin UL Flame;
Exterior Material: PBT Resin UL Flame;
Retardant Rating: 94-V0;
Interior Insulation: Epoxy Encapsulated;
Isolation Current: 2500 Vrms for 1 Minute;
Dielectric Resistance: 1000 M Ohms @ 500 VDC;
Surge Withstand: 5000V;
Rated Load Resistance: 100K Ohms;
Operating Temperature: -25 to +55c, -40 to;
|
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Standards: IEC/En60044-1 & IEC61010-1 & IEC61869-2;
Ratio: 1000: 1 or 2000:1 , Customized;
Nominal Input Current: 20 a/30A/40A/50A/60A/80A/100A/150A/200A;
Overload Withstand: 1.2 Times Rated Current Continuously;
Accuracy: 0.2%, 0.5 %, 1%;
System Voltage: 720V(0.72kv);
Output Signal: 10mA-200mA AC Optonal 333mv AC or 100mv-2V Optonal;
Frequency Range: 40 Hz-500 Hz;
Output: Standard 2.5 Meter Cable;
Max. Jaw Opening: 16 mm;
|
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Standards: IEC60044-1; IEC 61869-2; Ntc 2205; GB1208-2006; an;
Accuracy Class: 0.5s, 0.5%, 1%, 3%;
Range of Primary Rated Current: 100-1500A;
Range of Rated Load: ≤10va;
Rated Frequency: 50/60Hz;
Rated Secondary Current: 5A or 1A;
Safety Factor Rating: (Fs) <10;
Output Signal: 1A, 5A, 333mv, 1V or 5V(Customized);
Cable Length: 2.5m, 5m, 10m(Customized);
Aperture (mm): Φ55;
|
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Standards: IEC60044-1; IEC 61869-2; Ntc 2205; GB1208-2006; an;
Accuracy Class: 0.5s, 0.5%, 1%, 3%;
Range of Primary Rated Current: 100-1500A;
Range of Rated Load: ≤10va;
Rated Frequency: 50/60Hz;
Rated Secondary Current: 5A or 1A;
Output Signal: 1A, 5A, 333mv, 1V or 5V(Customized);
Cable Length: 2.5m, 5m, 10m(Customized);
Aperture (mm): Φ55;
Weight (Kg): 2;
|
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Standards: IEC60044-1; IEC 61869-2; Ntc 2205; GB1208-2006; an;
Accuracy Class: 0.5%, 1%;
Range of Primary Rated Current: 300-3000A;
Range of Rated Load: ≤25va;
Rated Frequency: 50/60Hz;
Rated Secondary Current: 5A or 1A;
Output Signal: 1A, 5A, 333mv, 1V or 5V(Customized);
Cable Length: 2.5m, 5m, 10m(Customized);
Aperture (mm): Φ185;
Weight (Kg): 4.5;
|