Specification |
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio, Medical;
Type: Toroidal Style Split Core Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Electronic, Instrument, Position Sensor, Audio, Li;
Winding Form: Single Layer & Tightly Wound Type;
Installation: Wire Leads;
Voltage Transformation Principle: 0.333-3.53V Output Voltage;
Core: Core-Type Transformer;
Cooling Method: Dry-Type Transformer;
Winding Type: Multi-Winding Transformer;
Frequency Characteristics: 50/60Hz;
Shape of Core: Single Stage Type;
Brand: Grewin;
Model No: Sct 100A Split Core Current Sensor;
Protection: 5 Times Protection, 10 Times Protecti;
Rated Load: 1, 2.5, 5.0, 10, 30va;
Frequency Range: 50/60Hz;
Output Split Core C: Standard:IEC 60044-1;
|
Application: Electronic;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Insulating Paper;
Installation: Busbar Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
|
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Insulating Paper;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Model: Hact;
Design Advantage: Clamp on Cts;
Accuracy: 0.5/1.0;
Rated Input: 5A-630A;
Rated Output: 40mA-100mA,0.333V;
Window Size: Check Specification Below;
Insulation Resistance: DC500V/100mΩ Min;
Frequency: 50-2kHz;
Dielectric Strength: 2.5kv/1mA/1min;
Operating Temp: -25ºC~75ºC;
|
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Insulating Paper;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Model: UK;
Design Advantage: Clamp on Cts;
Accuracy: 0.5/1.0/3.0;
Rated Input: 100A-1000A;
Rated Output: 1A/5A;
Window Size: Check Specification Below;
Insulation Resistance: DC500V/100mΩ Min;
Frequency: 50-2kHz;
Dielectric Strength: 2.5kv/1mA/1min;
Operating Temp: -25ºC~75ºC;
|
Application: Electronic, Instrument, Position Sensor;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Measuring Current Range: 0-1500A;
Current Output: 0-500mA/0.333V;
Class: 1.0;
|