Specification |
Application: Electronic, Instrument, Position Sensor, Audio, Lighting, Voltage Current Transformer;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement, Voltage, Power and Energy Monitoring D;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Accuracy: 0.2 0.5 Voltage Current Transformer;
Isolation Voltage: 2500 Vrms for 1 Minute;
Dielectric Resistanc: 1000 M Ohms @ 500 VDC;
Rated Load Resistance: 100K Ohms;
Operating Temperature: -25 to +55c, -40 to +85c Optional;
Frequency: 50 to 400 Hz;
Accuracy Class: as Defined in IEC 60044-2 Part 2 Volta;
Input Voltage: 57.7V-600V;
|
Application: Electronic, Instrument, Position Sensor, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Clamp Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Ratio: 1000: 1 or 2000:1 (Customized);
Accuracy Class: 0.2%, 0.5%, 1%;
Primary Current: 0 - 1000A AC;
Secondary Current: 0 - 5A AC (Customized);
Max. Cont. Input Current: 1200A;
Output Signal (AC Current): 500mA,1A,5A AC at Nominal Input Current;
Standards: En 61010-1, En 61010-2-032, IEC60044-1;
Max. Voltage Not Insulated Conductors: 600 V;
Max. Jaw Opening (mm): 60;
Holding Wire Diameter (mm): φ60 X 70;
|
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Standards: IEC60044-1; IEC 61869-2; Ntc 2205; GB1208-2006; an;
Accuracy Class: 0.5s, 0.5%, 1%, 3%;
Range of Primary Rated Current: 100-1500A;
Rated Frequency: 50/60Hz;
Range of Rated Load: 10va;
Rated Secondary Current: 5A or 1A;
Aperture (mm): 55;
Weight (Kg): 2;
Ingress Protection: IP65;
Environment: Outdoors or Indoors;
|
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Standards: IEC60044-1; IEC 61869-2; ANSI C57.13; Ntc 2205; GB;
Rated Primary Current: 20-600A;
Rated Load: 25va;
Rated Frequency: 50Hz or 60Hz;
Rated Secondary Current: 5A or 1A;
Weight (Kg): 3.1;
Accuracy Class: 0.5%, 1%, 3%;
Color: Red, Black;
|
Application: Electronic, Instrument, Current Measurement;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Standards: IEC60044-1; IEC 61869-2; ANSI C57.13; Ntc 2205; GB;
Rated Primary Current: 30-600A;
Rated Load: 10va;
Rated Frequency: 50Hz or 60Hz;
Rated Secondary Current: 5A or 1A;
Weight (Kg): 1.6;
Accuracy Class: 0.5s, 0.5%, 1%, 3%;
Color: Red, Black;
Keyword: Split Core Current Transformer;
Weight: 2kg;
|