Voltage Sensor Calibrator
US$1,000.00-100,000.00 / Piece
View

TUNKIA TI5100 DC High Voltage Sensor Transformer  Transducer Test Bench Calibration Device with DC Power Standard Source Video

About this Item
Details
Company Profile

Price

Min. Order Reference FOB Price

1 Piece US$1,000.00-100,000.00 / Piece

Sepcifications

  • After-sales Service Life Time
  • Warranty 12 months Excellent After-sales Service
  • Application Electromagnetic Instrument, Electrical Calibration
  • Customized Non-Customized
  • Transport Package Package for Exporting
  • Trademark TUNKIA
  • Origin China
  • DC High Voltage Standard Source 1 V~N kV
  • Accuracy Class 0.02, Class 0.05
  • Voltage measurement range ±(10 mV ~ 12 V)
  • Current Measurement Range ±(1 mA ~ 1.1 A)
  • High Frequency Voltage Source 10 mV~11 V, (DC,10 Hz ~ 1 MHz)
  • Pulse Voltage Source Range 200V~2kV
  • High Frequency Coaxial Shunt 100 mA and 1 A to1V

Product Description

TI5100 DC High Voltage Sensor Testing Device 1.Summary TI5100 is a multifunctional device for testing the measurement performance of DC high-voltage sensors. It consists of a DC high-standard source, sensor secondary signal measurement module, auxiliary power supply, sensor test tooling, ...

Learn More

Voltage Sensor Calibrator Comparison
Transaction Info
Price US $ 1,000.00-100,000.00/ Piece US $ 5000/ Piece US $ 55/ Piece US $ 55/ Piece US $ 15000/ Piece
Min Order 1 Pieces 1 Pieces 1 Pieces 1 Pieces 1 Pieces
Trade Terms - - - - -
Payment Terms L/C, T/T, D/P, Western Union, Paypal, Money Gram L/C, T/T, D/P, Western Union, Paypal L/C, T/T, D/P, Western Union, Paypal L/C, T/T, D/P, Western Union, Paypal L/C, T/T, D/P, Western Union, Paypal
Quality Control
Product Certification - CE CE CE CE
Management System Certification ISO 9001, ISO 14001 ISO 9001, ISO 14001 ISO 9001, ISO 14001 ISO 9001, ISO 14001 ISO 9001, ISO 14001
Trade Capacity
Export Markets Europe, Southeast Asia/ Mideast, East Asia(Japan/ South Korea), Domestic North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
Annual Export Revenue - - - - -
Business Model OEM, ODM, Own Brand OEM, ODM, Own Brand OEM, ODM, Own Brand OEM, ODM, Own Brand OEM, ODM, Own Brand
Average Lead Time - Off-season: within 15 Day(s)
Peak-season: 1 Month(s)
Off-season: within 15 Day(s)
Peak-season: 1 Month(s)
Off-season: within 15 Day(s)
Peak-season: 1 Month(s)
Off-season: within 15 Day(s)
Peak-season: 1 Month(s)
Product Attributes
Specification
After-sales Service: Life Time;
Warranty: 12 months Excellent After-sales Service;
Application: Electromagnetic Instrument, Electrical Calibration;
Customized: Non-Customized;
DC High Voltage Standard Source: 1 V~N kV;
Accuracy: Class 0.02, Class 0.05;
Voltage measurement range: ±(10 mV ~ 12 V);
Current Measurement Range: ±(1 mA ~ 1.1 A);
High Frequency Voltage Source: 10 mV~11 V, (DC,10 Hz ~ 1 MHz);
Pulse Voltage Source Range: 200V~2kV;
High Frequency Coaxial Shunt: 100 mA and 1 A to1V;
Application: Mechanical Instrument, Electromagnetic Instrument;
Power: Electricity;
Voltage Output: 220V;
Current Output: 0-1000A;
Customized: Customized;
Key Words: Primary Injection Kit 1000 AMP Price;
Accuracy: ±0.5%;
Current Output (AC): 1000A·5V or 500A·10V;
Key Word: Current Injection Test for Cables at Mumbai;
Capacity: 5kVA;
The Current Output Waveform Distortion: ≤5%;
Primary Current: 0-1100A;
Secondary Measurement: 0-6A;
Model: Primary Injection Kit;
Current Duration: 1000A 2-3minutes;
Application: Mechanical Instrument, Electromagnetic Instrument;
Power: Electricity;
Voltage Output: 220V;
Current Output: 0-2000A;
Customized: Customized;
Key Words: Current Injector Equipment;
Accuracy: ±0.5%;
Current Output (AC): 2000A·6V or 1000A·12V;
Key Word: Injection Test Equipment;
Capacity: 12kVA;
The Current Output Waveform Distortion: ≤5%;
Primary Current: 0-2200A;
Secondary Measurement: 0-6A;
Model: Current Injection Testers;
Current Duration: 2000A 2-3minutes;
Application: Mechanical Instrument, Electromagnetic Instrument;
Power: Electricity;
Voltage Output: 220V;
Current Output: 0-3000A;
Customized: Customized;
Key Words: Current Injector Supplier;
Accuracy: ±0.5%;
Current Output (AC): 3000A·5V or 1500A·10V;
Key Word: Current Injector 3000 AMP;
Capacity: 15kVA;
The Current Output Waveform Distortion: ≤5%;
Primary Current: 0-3300A;
Secondary Measurement: 0-6A;
Model: Transformer Primary Injection Test;
Current Duration: 3000A 2-3minutes;
Application: Mechanical Instrument, Electromagnetic Instrument;
Power: Electricity;
Voltage Output: 380V;
Current Output: 0-5000A;
Customized: Customized;
Key Words: Current Injection for CT Testing;
Accuracy: ±0.5%;
Current Output (AC): 5000A·5V or 2500A·10V;
Key Word: 4000A Primary Current Injector;
Capacity: 25kVA;
The Current Output Waveform Distortion: ≤5%;
Primary Current: 0-5500A;
Secondary Measurement: 0-6A;
Model: Electric Current Injector;
Current Duration: 5000A 2-3minutes;
Supplier Name

Tunkia Co., Ltd.

China Supplier - Gold Member Audited Supplier

Beijing GFUVE Electronics Co., Ltd.

China Supplier - Gold Member Audited Supplier

Beijing GFUVE Electronics Co., Ltd.

China Supplier - Gold Member Audited Supplier

Beijing GFUVE Electronics Co., Ltd.

China Supplier - Gold Member Audited Supplier

Beijing GFUVE Electronics Co., Ltd.

China Supplier - Gold Member Audited Supplier