Specification |
Classification: Physiological Functions of Diagnosis and Monitoring Equipment;
Type: Aed;
Group: Adult PED;
Product Name: Aed;
Carry Bag: Yes;
Application: Adult, Pediatric;
Language: English, French, Spanish, Germany, Italy, Portugue;
Charge Time: 7 Sec. to 150j, 11 Sec. to 200j;
OEM: Acceptable;
Waveform: Biphasic;
Battery: Non-Rechargeable. 12V, 3000mAh;
Aed Pad: Disposable;
Voice Prompt: Yes;
Analysis Time: 9 Sec;
ECG: Optional;
Weight: 1.9kg;
MOQ: 1;
Dimension: 256*220*80mm;
|
Classification: Biochemical Apparatus;
Type: Digital Imaging System;
Group: Middle-aged and Old;
Block Formats: 96-Well;
Dynamics Range: 1-10^10 Copies;
Heating/Cooling Rate: 0.1~4.2ºC/S;
Excitation Wavelength: 300-800nm;
Emission Wavelength: 500-800nm;
Reaction System: 5~100μl;
Sample Capacity: 96X0.2ml PCR Plate, 12X8-Strip Tubes, 96*0.2ml Si;
Product Name: Fluorescence Quantitative PCR Detection System;
Ramprate: 4.0ºC/S(Max);
Temp. Control Accuracy: ±0.1ºC;
Temp. Uniformity: ≤ ±0.3ºC;
Temp. Control Mode: Block Mode Andtube Mode (Automaticcontrolbasedonli;
Operation Mode: Continuous Operation;
Gradient Temp. Range: 1-36ºC;
Hot-Lid Temp. Range: 30-110;
|
Classification: Biological Diagnostics;
Type: Nucleic Acid Extractor;
Group: All;
Sample Quantity: 32;
Status: in Stock;
Sample Volume: 20-500UL;
Sample Throughput: 1-32;
Magnetic Bead Recovery: >98%;
Extracting The Difference Between Holes: 3%;
Heating Temperature: 8 Independent Heating Modules;
Reagent Type: Magnetic Bead Open Platform;
Extraction Time: 15-40 Min/Round;
Internal Program: Be Able to Store;
|
Classification: Physiological Functions of Diagnosis and Monitoring Equipment;
Type: Urine Analyzer;
Group: All;
Model Number: Bh-Ny01;
Material: ABS;
Size: 340*340*220mm;
Capacity: 700tests/Hour;
Product Name: Urine Analyzer;
Principle: Reflection of High-Brightness Cold Light;
Printer: Built-in Thermal Printer,Paper Type 57mm;
Instrument Classification: Class I;
Working Environment: Temperature:15~35ºC; Humidity: 10~85%;
Interface: Standard RS-232port;
Function: Detecting Body Health;
Application: hospital;
Timing Range: 1~9999 Minutes (Hours) or Continuous Operation;
Throughput: 700tests/Hour;
Cuvette: Disposable Cuvette;
|
Classification: Biochemical Apparatus;
Type: Digital Imaging System;
Group: Middle-aged and Old;
Model No.: Leia-X4;
Reaction System: 4;
Detector: Mppc;
Detection Wavelength: 510~730nm;
Scanning Mode: Full Plate Scanning;
Sample Capacity: 96X0.1ml PCR Plate, 12X8-Strip Tubes, 96*0.1ml Sin;
Emission Light: LED;
Excitation Wavelength: 455~680nm;
Gradient Temp. Range: 1-36c;
Channel: 4;
Dynamics Range: 1-1010 Copies;
Warranty: 12 Months;
Model Number: Leia-X4;
Port Method: USB Port;
Gross Weight: 48;
|