Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: ELCB;
Poles Number: 2;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, RCCB;
OEM: Yes;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1/2/3/4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
Product Name: DC MCB;
Votage: 440V 550V 800V 1000V 1200V 1500V;
Ampes: 6,10,16,20,25,32,40,50,63A;
Pole: 4p;
Curve Type: C;
Trip Type: Thermal-Magnetic;
Installation Category: Class III;
Pollution Level: 3;
Installation Environment: No Obvious Shock and Vibration;
Ambient Tempersture: -20--70;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1/2/3/4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
Product Name: Meanray Single Phase Types Circuit Protector 250V;
Votage: 440V 550V 800V 1000V 1200V;
Ampes: 6,10,16,20,25,32,40,50,60A;
Pole: 1p,2p,3p,4p;
Curve Type: C;
Trip Type: Thermal-Magnetic;
Installation Category: Class III;
Pollution Level: 3;
Installation Environment: No Obvious Shock and Vibration;
Ambient Tempersture: -20--70;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1/2/3/4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
Product Name: Meanray Non-Polarity DC 1000V 1200V 32A MCB;
Votage: 440V 550V 800V 1000V 1200V;
Ampes: 6,10,16,20,25,32,40,50,60A;
Pole: 1p,2p,3p,4p;
Curve Type: C;
Trip Type: Thermal-Magnetic;
Installation Category: Class III;
Pollution Level: 3;
Installation Environment: No Obvious Shock and Vibration;
Ambient Tempersture: -20--70;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1/2/3/4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker;
Product Name: TUV L7 New Type 1000V DC Circuit Breaker,Miniature;
Votage: 440V 550V 800V 1000V 1200V;
Ampes: 6,10,16,20,25,32,40,50,60A;
Pole: 1p,2p,3p,4p;
Curve Type: C;
Trip Type: Thermal-Magnetic;
Installation Category: Class III;
Pollution Level: 3;
Installation Environment: No Obvious Shock and Vibration;
Ambient Tempersture: -20--70;
|