Specification |
After-sales Service: 24/7 Online Service;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: Gamma Ray Spectrometer;
Gaspath System: Single;
Detector: TCD;
Energy Resolution: ≤7%;
Spectrometer Detector: SDD;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 20~40mm;
Product Name: Oil Gas Chromatograph;
Voltage Range: 0.5~10kv;
Test Current Range: 10μa~1A;
Power Factor: 0.02 < Cos φ < 0.1;
Current Range: 0.5A ~ 15A (Internal), 0.5A ~ 50A (External);
Frequency Measuremen: 45 ~ 65Hz;
Ambient Temperature: -10°c to 50°c;
Ambient Humidity: ≤85℅rh, Non-Condensing;
Operating Power Supply: AC220V ±10%;
|
After-sales Service: Online Support;
Warranty: 1 Year;
Appliance: Medical Research;
Ray Type: /;
Gaspath System: /;
Detector: UV/Vis Detector;
Energy Resolution: /;
Spectrometer Detector: /;
Stationary Phase: /;
Mobile Phase: /;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: /;
Chromatographic Column Length: /;
Chromatographic Column Diameter: /;
Model: Bk-Lci1100;
Double Plunger Reciprocating Pump: 1 Set;
Flow Range: 0.001ml/Min-10.000ml/Min;
Setting Step Size: 0.001ml/Min;
Flow Accuracy: ≤±0.3% (1.00ml/Min, H2O, R.T., 8.5MPa);
Flow Stability: Rsd≤0.1% (1.00ml/Min, H2O, R.T., 8.5MPa);
Maximum Pressure: 42MPa;
Display Pressure Error: <+-3.0%;
Pressure Fluctuation: <1.0%;
Power Dissipation: 80W;
Wavelength Range: 190-700nm;
Wavelength Repeatability: +-0.1nm;
Wavelength Accuracy: <+-1.0nm;
Spectrum Band Width: 8nm;
Response Time: 0.0s-4.9s;
|
After-sales Service: Online Training;
Warranty: 1 Year;
Appliance: Biochemistry;
Gaspath System: Single;
Energy Resolution: ≤7%;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Name: High Performance Liquid Chromatography;
Model: Bk-Lci5100;
Type: Isocratic Pump;
Flow Rate Range: 0.001ml/Min-10.000ml/Min;
Flow Accuracy: ≤±0.2%;
Flow Precision: Rsd≤0.06%;
Maximum Pressure: 63MPa;
Pressure Accuracy: ≤±3.0%;
Pressure Pulsation: ≤0.1MPa;
Wavelength Range: 190-800nm;
Wavelength Repeatability: ≤0.1nm;
Wavelength Accuracy: ≤±1.0nm;
Band Width: 8nm;
Power Supply: AC110/220V±10%, 50/60Hz;
Gross Weight: 156kg;
|
After-sales Service: Online Training;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Gaspath System: Single;
Energy Resolution: ≤7%;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Name: High Performance Liquid Chromatography;
Model: Agress1100(Type I);
Quantity: 1 Set;
Flow Rate Range: 0.001ml/Min-10.000ml/Min;
Flow Accuracy: ≤±0.2%;
Flow Precision: Rsd≤0.075%;
Maximum Pressure: 45MPa;
Pressure Accuracy: ≤±3.0%;
Pressure Pulsation: ≤0.1MPa;
Wavelength Range: 190-700nm;
Wavelength Repeatability: ≤0.1nm;
Wavelength Accuracy: ≤±1.0nm;
Band Width: 8nm;
Power Supply: AC110/220V±10%, 50/60Hz;
Gross Weight: 68kg;
|
Appliance: Trace Impurity Analysis;
Gaspath System: Single;
Detector: Fid and Tcd;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Packed Column Injection and Capillary Injection;
Temperature Area: Column Oven, Sampler, Detector;
Temperature Range: Room Temperature up 7ºC~ 420 ºC;
Max Installation Qty: 2;
Ignition Model: Automatic;
Hydrogen Flame Lonization Detector: Logarithmic Amplifier;
Voltage: 220V~±22V 50Hz±0.5Hz;
Power: 220V±22V, 50Hz±0.5Hz, 3000W;
Package Size: 735mmx725mmx835mm;
G.W: 82kg;
N.W.: 70kg;
|