Specification |
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Energy-storage Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Vcb;
Poles Number: 1;
Type: Vacuum;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Voltage: 15 Kv;
Mechanical Life: 10000;
Rated Peak Withstand Current: 125ka;
Rated Lightning Impulse Withstand Voltag: 125kv;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 1p, 2p, 3p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Cooperation Type: ODM OEM;
Production Line: 100% Automatic;
Rated Current: 1-40A;
Payment: L/C T/T D/P Western Union Paypal Money Gram;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Electricity Type: Vacuum;
Number of Pole: 1;
Main Circuit Rating Current: 630A;
Phase: 1/2/3;
Main Circuit Rating Voltage: 12KV;
Name: Vacuum Interrupter;
Shelf life: 20years;
Color: Silver, Copper;
Afterserivce: Yes;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Economy Model 60 Series;
Installation: Open Frame;
Structure: ELCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Standard: IEC/En60898-1,GB10963.1;
Frame Current(Lm): 63A;
Rated Current(Ln): 6/10/16/20/25/32/40/50/63A;
Rated Operating Frequency: 50/60Hz;
Rated Impulse Voltage(Ui): 500V;
Rated Voltage(Ue): 230V(1p,1p+N),400V(2p-4p,3p+N);
Pole: 1p/1p+N/2p/3p/3p+N/4p;
Rated Impulse Withstand Voltage(Uimp): 4kv;
Rated Short-Circuit Breaking Capacity(IC: 4.5/6ka;
Rated Operating Breaking Capacity(Ics): 4.5/6ka;
Mechanical Life: 10000time;
Electrical Life: 6000time;
Trip Curve: B/C/D;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Economy Model 60 Series;
Installation: Open Frame;
Structure: ELCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Standard: IEC/En60898-1,GB10963.1;
Frame Current(Lm): 63A;
Rated Current(Ln): 6/10/16/20/25/32/40/50/63A;
Rated Operating Frequency: 50/60Hz;
Rated Impulse Voltage(Ui): 500V;
Rated Voltage(Ue): 230V(1p,1p+N),400V(2p-4p,3p+N);
Pole: 1p/1p+N/2p/3p/3p+N/4p;
Rated Impulse Withstand Voltage(Uimp): 4kv;
Rated Short-Circuit Breaking Capacity(IC: 4.5/6ka;
Rated Operating Breaking Capacity(Ics): 4.5/6ka;
Mechanical Life: 10000time;
Electrical Life: 6000time;
Trip Curve: B/C/D;
|