Specification |
After-sales Service: 1y;
Application: Laboratory Apparatus;
Warranty: > 1Year;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: New Spectrometer;
Wavelengths: UV Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Customized;
|
After-sales Service: on Line Service;
Application: Laboratory Apparatus;
Warranty: > 1Year;
Detection Method: Spectrophotometer;
Principle: New Spectrometer;
Wavelengths: UV Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Polychromator;
Customized: Customized;
Product Name: 1nm Spectral Bandwidth Double Beam UV/Vis Spectrop;
Model: Nu-T1810d;
Optical System: Double Beam, Grating 1200 Line/mm;
Wavelength Range: 190-1100nm;
Spectral Bandwidth: 1nm;
Wavelength Accuracy: +-0.3nm;
Wavelength Repeatability: +-0.1nm;
Stray Light: <=0.03%T, @220nm/360nm;
Noise Level: +-0.0008ABS;
Stability: +-0.0008A/H@500nm;
Baseline Flatness: +-0.001ABS;
Baseline Dark Noise: 0.08%T;
Photometric Range: 0- 200 Percenty T;
Light Source: Tungsten and Lamp;
Scan Speed: Hi,Med.,Low.,Max.;
|
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: New Spectrometer;
Wavelengths: 190nm-900nm;
Customized: Customized;
Monochromator: C-T, Aberration;
Spectrum Bandwidth: 0.2nm, 0.4nm, 1.0nm, 2.0nm for Option;
Wavelength Accuracy: ±0.25nm;
Wavelength Repeatability: 0.15nm;
Baseline Shift: ±0.004A/30min;
Detector: Photomultiplier;
|
After-sales Service: One Year Warranty;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Wavelengths: Wavelength: 190nm-900nm;
Customized: Customized;
Monochromator: C-T, Aberration;
Spectrum Bandwidth: 0.2nm, 0.4nm, 1.0nm, 2.0nm for Option;
Wavelength Accuracy: ±0.10nm;
Wavelength Repeatability: 0.05nm;
Detector: Photomultiplier;
Resolution: in 0, 2nm Spectral Bandwidth to Separate Mn Double;
|
After-sales Service: One Year Warranty;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Wavelengths: Wavelength: 190nm-900nm;
Customized: Customized;
Monochromator: C-T, Aberration;
Wavelength Accuracy: ±0.15nm;
Wavelength Repeatability: <0.10nm;
Baseline Shift: 0.004A/30min;
Detector: High Sensitivity Photomultiplier;
Spectrum Bandwidth: 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm for Option;
|