Specification |
Type: Low-voltage;
Structure: Single-column Disconnector;
Installation: Indoor High-voltage;
Operation: Electric;
Grounding Mode: Not Grounding;
Movement Mode: Horizontal Rotary Type;
Number of Poles: Three Pole;
Grounding: Double Ground;
Series: Three;
Run: Turn the Horizontal;
Switching Mode: Single Throw-in;
Common Model: Hgl;
Structure of Operating: Electric;
Brand: Yom;
Print: According to Customer Requirements;
Available Service: OEM,ODM;
Package: Inner Box+ Outer Carton;
Delivery: by Sea / by Train/ by Truck;
Term: Fca/EXW/ Fob/CIF;
|
Type: Low-voltage;
Structure: Double-column Disconnector;
Installation: Outdoor High-voltage;
Operation: Manual;
Grounding Mode: Grounding;
Movement Mode: Horizontal Rotary Type;
Number of Poles: Unipolar;
Grounding: Single Ground;
Series: Three;
Run: Plug-In;
Switching Mode: Single Throw-in;
Structure of Operating: Manual;
Brand: Elmak;
Warranty: 3 Years;
Material: PC;
Certificate: SAA;
MOQ: 100;
Place of Origin: Zhejiang, China;
Standard: Australia Standard;
Voltage: 220-240V;
Weight (Kg): 0.4;
|
Type: Low-voltage;
Structure: Single-column Disconnector;
Installation: Outdoor High-voltage;
Operation: Electric;
Grounding Mode: Grounding;
Movement Mode: Vertical Rotary Type;
Number of Poles: Three Pole;
Grounding: Single Ground;
Series: Three;
Run: Vertical Rotation;
Switching Mode: Single Throw-in;
Common Model: YR;
Structure of Operating: Electric;
Brand: Aswich;
Rated Insulation Voltage Ui: 800V;
Rared Current: 16, 20, 25, 32, 40, 63, 80, 100,125A;
Pole: 2p, 3p, 4p, 6p,8p;
Rated Impulse Withstand Voltage Uimp: 8kv;
IP Code: IP66;
Certificates: CE, TUV;
Rated Short-Time Withstand Current: 20A, 35A, 63A;
Rated Conditional Short-Circuit Current: 1.5ka;
Rated Short-Time Making Capacity: 0.76ka, 1s;
Rated Insulation Voltage (Le): 50/60Hz;
Pollution Degree: 3;
Auxiliary Contacts Code: P1 1no+1nc, P2 2no;
Mechanical Endurance: 100000;
Interrupting Medium: Air;
Ambient Temperature: Operating -25~+55ºC Storage-40~+70ºC;
|
Type: Low-voltage;
Structure: Single-column Disconnector;
Installation: Outdoor High-voltage;
Operation: Electric;
Grounding Mode: Grounding;
Movement Mode: Vertical Rotary Type;
Number of Poles: Three Pole;
Grounding: Single Ground;
Series: Three;
Run: Vertical Rotation;
Switching Mode: Single Throw-in;
Common Model: YR;
Structure of Operating: Electric;
Brand: Aswich;
Rated Insulation Voltage Ui: 800V;
Rared Current: 16, 20, 25, 32, 40, 63, 80, 100,125A;
Pole: 2p, 3p, 4p, 6p,8p;
Certificates: CE, TUV;
IP Code: IP66;
Rated Short-Time Withstand Current: 20A, 35A, 63A;
Rated Impulse Withstand Voltage Uimp: 8kv;
Rated Conditional Short-Circuit Current: 1.5ka;
Rated Short-Time Making Capacity: 0.76ka, 1s;
Rated Insulation Voltage (Le): 50/60Hz;
Pollution Degree: 3;
Auxiliary Contacts Code: P1 1no+1nc, P2 2no;
Mechanical Endurance: 100000;
Interrupting Medium: Air;
Ambient Temperature: Operating -25~+55ºC Storage-40~+70ºC;
|
Type: Low-voltage;
Structure: Single-column Disconnector;
Installation: Outdoor High-voltage;
Operation: Electric;
Grounding Mode: Grounding;
Movement Mode: Vertical Rotary Type;
Number of Poles: Three Pole;
Grounding: Single Ground;
Series: Three;
Run: Vertical Rotation;
Switching Mode: Single Throw-in;
Common Model: YR;
Structure of Operating: Electric;
Brand: Aswich;
Rated Insulation Voltage Ui: 800V;
Rared Current: 16, 20, 25, 32, 40, 63, 80, 100,125A;
Pole: 2p, 3p, 4p, 6p,8p;
Rated Impulse Withstand Voltage Uimp: 8kv;
IP Code: IP66;
Certificates: CE, TUV;
Rated Short-Time Withstand Current: 20A, 35A, 63A;
Rated Conditional Short-Circuit Current: 1.5ka;
Rated Short-Time Making Capacity: 0.76ka, 1s;
Rated Insulation Voltage (Le): 50/60Hz;
Pollution Degree: 3;
Auxiliary Contacts Code: P1 1no+1nc, P2 2no;
Mechanical Endurance: 100000;
Interrupting Medium: Air;
Ambient Temperature: Operating -25~+55ºC Storage-40~+70ºC;
|