Specification |
Equipment Type: Fully Automatic Discrete, Stat Priority;
Analysis Rate: Constant Speed 200t/H (Without ISE);
Test Principle: Colorimetry, Turbidimetry;
Sample Tray: 42 Sample Positions, Random Access of All Samples;
Sample Volume: 2-50UL, 0.1UL Increment;
Reagent Tray: 25 Reagent Positions;
Reagent Volume: R1:25-300UL, R2:10-150UL, 0.1UL Increment;
Reaction Tray: Rotating Tray, 120 Cuvettes;
Reaction Volume: 180-500UL;
Temperature: 37ºC±0.1ºC with Real-Time Display;
|
Product Name: Infusion Pump Vp3;
Power Supply: AC100-220V, 50/60Hz;
Infusion Accuracy: 2%;
Features: Easy to Carry, Easy to Operate;
Infusion Set: Any Brand of Infusion Set;
Infusion Mode: Rate, Time, Dose, Drug Library and Sequential Mode;
Air Bubble Detection: Ultrasound Sensor Detection of Air Bubble;
Model No.: Infusion Pump;
Brightness: 1~10 Levels Can Be Selected;
Purge Rate: 600.0ml/H (Adjustable);
Total Volume Range: 0.0-9999ml (1 Ml Step);
Kvo Rate: 0.1~5.0ml/H. Programmable and Adjustable;
Occlusion Pressure: 24 Levels, 30K PA- 160K PA;
History Records: 2000 Events Stored Can Be Checked and Downloaded;
Delivery Rate Range: 0.1ml/H~1500ml/H (0.1ml/H~99.9ml/H, 0.1ml/H Step;;
|
Product Name: Infusion Pump Vp3;
Power Supply: AC100-220V, 50/60Hz;
Infusion Accuracy: 2%;
Features: Easy to Carry, Easy to Operate;
Infusion Set: Any Brand of Infusion Set;
Infusion Mode: Rate, Time, Dose, Drug Library and Sequential Mode;
Air Bubble Detection: Ultrasound Sensor Detection of Air Bubble;
Model No.: Infusion Pump;
Brightness: 1~10 Levels Can Be Selected;
Purge Rate: 600.0ml/H (Adjustable);
Total Volume Range: 0.0-9999ml (1 Ml Step);
Kvo Rate: 0.1~5.0ml/H. Programmable and Adjustable;
Occlusion Pressure: 24 Levels, 30K PA- 160K PA;
History Records: 2000 Events Stored Can Be Checked and Downloaded;
Delivery Rate Range: 0.1ml/H~1500ml/H (0.1ml/H~99.9ml/H, 0.1ml/H Step;;
|
Type: Operation Apparatus;
Syringe: Disposable Sterile Syringe;
Blood Sampling Needle: No;
Breathing Pattern: No;
Animal Anesthesia Machine Control Method: No;
Warranty: 1 Year;
|
Product Name: Infusion Pump Vp3;
Power Supply: AC100-220V, 50/60Hz;
Infusion Accuracy: 2%;
Features: Easy to Carry, Easy to Operate;
Infusion Set: Any Brand of Infusion Set;
Infusion Mode: Rate, Time, Dose, Drug Library and Sequential Mode;
Air Bubble Detection: Ultrasound Sensor Detection of Air Bubble;
Model No.: Infusion Pump;
Brightness: 1~10 Levels Can Be Selected;
Purge Rate: 600.0ml/H (Adjustable);
Total Volume Range: 0.0-9999ml (1 Ml Step);
Kvo Rate: 0.1~5.0ml/H. Programmable and Adjustable;
Occlusion Pressure: 24 Levels, 30K PA- 160K PA;
History Records: 2000 Events Stored Can Be Checked and Downloaded;
Delivery Rate Range: 0.1ml/H~1500ml/H (0.1ml/H~99.9ml/H, 0.1ml/H Step;;
|