Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: RCBO;
Poles Number: 4;
Type: Circuit Breaker;
Function: Overcurrent Protection, Short circuit;
Standard: IEC 61009-1;
Pole: 4P, 2P;
Tripping curve: B,C,D;
Rated Current (in): 63A;
Mode: Electromagnetic;
Residual Current Type: A;
Residual Current (LΔn): 30mA,100mA,300mA;
Icn: 6KA,10KA;
Energy limiting class: 3;
Electrical Life: 20, 000;
Mechenical Life: 20, 000;
keywords: residual current device types;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Conventional Circuit Breaker;
Poles Number: 3;
Type: Circuit Breaker;
Function: Overcurrent Protection, Circuit-Breaker Failure P;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: MCB;
Poles Number: 2;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection, Miniature Circuit Breaker;
Package: Original Package;
Amperage Rating: 15A;
Frequency Rating - max: 60 HZ;
Frequency rating - min: 50 HZ;
Number of Poles: 2;
Product Length/Depth: 105 mm;
Product Height: 75.5 mm;
Product Width: 35.4 mm;
Product Weight: 0.247 kg;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Oil-immersed Type;
Installation: Fixed;
Structure: ACB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, RCCB;
Dielectric Test Voltage: 50/60 Hz-1 Min: 2 Kv;
Power Supply Connection: Arbitrary;
Contact Position Indication: on / off;
Energy Limiting Class: 3;
Electrical Endurance: 20000 AC Cycle;
Mechanical Endurance: 20000 Cycle;
Number of Protected Poles: 2;
Number of Poles: 2p;
Tightening Torque: 2 N·m;
Actuator Type: Toggle;
Screw Terminal Type: Cage Terminal;
Actuator Marking: I / O;
Actuator Material: Insulation Group II, Black, Sealable;
Recommended Screw Driver: Pozidriv 2;
Accessories Available: No;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Oil-immersed Type;
Installation: Fixed;
Structure: ACB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, RCCB;
Dielectric Test Voltage: 50/60 Hz-1 Min: 2 Kv;
Power Supply Connection: Arbitrary;
Contact Position Indication: on / off;
Energy Limiting Class: 3;
Electrical Endurance: 20000 AC Cycle;
Mechanical Endurance: 20000 Cycle;
Number of Protected Poles: 2;
Number of Poles: 2p;
Tightening Torque: 2 N·m;
Actuator Type: Toggle;
Screw Terminal Type: Cage Terminal;
Actuator Marking: I / O;
Actuator Material: Insulation Group II, Black, Sealable;
Recommended Screw Driver: Pozidriv 2;
Accessories Available: No;
|